Impact of ultrasonic image quality on the consistency of artificial intelligence assisted diagnosis system and manual measurements of biological indicators in children with developmental dysplasia of hip
10.13929/j.issn.1003-3289.2024.07.022
- VernacularTitle:声像图质量对人工智能辅助诊断系统与人工测量发育性髋关节发育不良患儿生物学指标一致性的影响
- Author:
Shuangshuang ZHANG
1
;
Xiaoyi CHEN
;
Wei SHI
;
Ziyi WANG
;
Tong HAN
;
Xin YANG
;
Dong NI
;
Bingxuan HUANG
;
Zhixia WU
;
Na XU
Author Information
1. 中国医科大学附属深圳市儿童医院超声科,广东 深圳 518000
- Keywords:
developmental dysplasia of the hip;
ultrasonography;
artificial intelligence;
image quality
- From:
Chinese Journal of Medical Imaging Technology
2024;40(7):1067-1071
- CountryChina
- Language:Chinese
-
Abstract:
Objective To observe the impact of ultrasonic image quality on the consistency of artificial intelligence(Al)assisted diagnosis system and manual measurements of biological indicators of developmental dysplasia of hip(DDH).Methods Hip ultrasonic data of 75 DDH and 345 non-DDH children were retrospectively analyzed,and the quality of ultrasonic images were subjectively scored.An evaluation model of ultrasonic image quality was constructed based on 140 ultrasonic images acquired from 140 cases(group A,containing 25 DDH and 115 non-DDH)using entropy weighting method,the weight of anatomic structures and impact factors related to DDH were obtained.The comprehensive image quality scores of other ultrasonic images acquired from 280 cases(group B,including 50 DDH and 230 non-DDH)were calculated,and the images in group B were classified into grade A,B and C in descending order.The consistency of AI and manual measurements of DDH biological indicators in group B was assessed.Results The weight of each anatomic structure and impact factors of DDH obtained with the model were as follows:The lower edge of iliac branch>ilium>glenoid labrum>bony margin>femoral head>motion artifacts.In group B,grade A was observed in 67(9 DDH and 58 non-DDH),grade B was found in 160(26 DDH and 134 non-DDH),while grade C was noticed in 53(15 DDH and 38 non DDH)images.Except for β,femoral head coverage(FHC)and femoral head length diameter,the consistencies between AI and manual measurements of other indicators of DDH were grade A>B>C.In group B,AI and manual measurements were more consistent in DDH than in non-DDH cases.Conclusion Ultrasonic image quality affected the consistency between AI and manual measurements of biological indicators of DDH.When image quality was not good enough,further attention should be paid to measurement of FHC and sizes of femoral head.