Reproducibility of virtual monoenergetic CT image-derived radiomics features:Experimental study
10.13929/j.issn.1003-3289.2024.05.017
- VernacularTitle:不同双能CT虚拟单能谱图像衍生影像组学特征的可重复性:实验研究
- Author:
Pengchao ZHAN
1
;
Xing LIU
;
Yahua LI
;
Kunpeng WU
;
Zhen LI
;
Peijie LYU
;
Pan LIANG
;
Jianbo GAO
Author Information
1. 郑州大学第一附属医院放射科,河南郑州 450052
- Keywords:
liver neoplasms,experimental;
rabbits;
tomography,X-ray computed;
radiomics;
reproducibility of results
- From:
Chinese Journal of Medical Imaging Technology
2024;40(5):712-717
- CountryChina
- Language:Chinese
-
Abstract:
Objective To observe the reproducibility of radiomics feature(RF)extracted from virtual monoenergetic image(VMI)of rabbit VX2 hepatoma models obtained with 3 different dual-energy CT(DECT)systems,and to explore relationship of reproducibility and diagnostic performance of RF.Methods Fifteen rabbits with VX2 hepatoma were randomly divided into 3 groups(each n=5).Contrast-enhanced abdominal CT scanning under volume CT dose index(CTDIvol)levels of 6,9 and 12 mGy were performed with dual-source DECT(dsDECT),rapid kV switching DECT(rsDECT)and dual-layer detector DECT(dlDECT),respectively.VMI were reconstructed at 10 keV increments from 40 to 140 keV.RF were extracted from VMI,the reproducibility was assessed using intra-class correlation coefficient(ICC),and those with ICC≥0.8 were considered as reproducible RF.The percentage of reproducible features(denoted by R)were compared among different scanner pairings and different CTDIvol levels.Within each CTDIvol group,the reconstruction energy levels yielding the maximum number(denoted by N)of common RF across different scanner pairings were identified.The receiver operating characteristic(ROC)curve was drawn,the area under the curve(AUC)was calculated,and the diagnostic efficacies of reproducible RF and other RF were compared under optimal reproducible conditions.Spearman correlation coefficient between ICC and the corresponding AUC of RF were calculated.Results RrsDECT-dsDECT(6.45%,95%CI[2.36%,8.87%])was higher than RdlDECT-dsDECT(0.72%,95%CI[0.15%,1.79%])and RrsDECT-dlDECT(1.43%,95%CI[0.60%,4.06%])(all adjusted P<0.05),R9mGy(3.70%,95%CI[1.31%,5.73%])and R12mGy(2.63%,95%CI[0.60%,6.69%])were higher than R6mGy(1.31%,95%CI[0.12%,1.55%])(all adjusted P<0.05).The optimal reproducible reconstruction energy levels of RF under CTDIvol of 6,9 and 12 mGy concentrated at 50-70 keV.AUC of reproducible RFs were higher than of other RF(all adjusted P<0.05)and had certain correlation with the reproducibility(rs=0.102-0.516,P<0.05).Conclusion The reproducibility of RF extracted from contrast-enhanced VMI CT images of rabbit VX2 hepatoma models associated with DECT scanner,CTDIvol level and reconstruction energy level.RF with higher reproducibility might have better diagnostic performance.