Susceptibility weighted imaging based on 5.0T MRI for diagnosing hepatocellular carcinoma complicated with vein tumor thrombi
10.13929/j.issn.1003-3289.2024.05.010
- VernacularTitle:基于5.0T MRI的磁敏感加权成像诊断肝细胞癌合并静脉癌栓
- Author:
Shaopeng LI
1
;
Chang LIU
;
Dawei YIN
;
Xiaopeng SONG
;
Runyu TANG
;
Kexue DENG
Author Information
1. 中国科技大学附属第一医院(安徽省立医院)南区影像中心,安徽合肥 230032
- Keywords:
carcinoma,hepatocellular;
embolism;
magnetic resonance imaging;
susceptibility-weighted imaging
- From:
Chinese Journal of Medical Imaging Technology
2024;40(5):682-685
- CountryChina
- Language:Chinese
-
Abstract:
Objective To observe the value of susceptibility weighted imaging(SWI)based on 5.0T MRI for diagnosing hepatocellular carcinoma(HCC)complicated with vein tumor thrombi.Methods Totally 63 HCC patients were retrospectively enrolled,among them 17 complicated with vein tumor thrombi.The efficacy of 5.0T SWI for detecting vein tumor thrombus was observed,and the image quality were compared between 5.0T and 3.0T.Results 5.0T SWI displayed vein tumor thrombi in 16 cases,except for 1 case with vein tumor thrombi in the upper segment of the left lateral lobe of the left portal vein.The liver edge score,overall image quality score,signal-to-noise ratio and contrast-to-noise ratio of portal venous phase and hepatobiliary phase in 5.0T enhanced MRI were all higher than those in 3.0T(all P<0.05).Conclusion 5.0T SWI was helpful for diagnosing HCC complicated with vein tumor thrombi.