Investigation on improving standard of polypropylene infusion bottles
10.19778/j.chp.2024.02.011
- VernacularTitle:聚丙烯输液瓶标准提高研究
- Author:
Xiang LI
1
;
Jinfeng ZHENG
;
Fang LIN
;
Yanhui XU
;
Xia ZHAO
Author Information
1. 福建省食品药品质量检验研究院,福州 350001
- Keywords:
polypropylene;
infusion bottles;
DSC;
standard improvement;
determination;
melting peak
- From:
Drug Standards of China
2024;25(2):176-180
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the use of differential scanning calorimetry(DSC)method to identify polypropyl-ene infusion bottles material.Methods:The thermal analysis curve under nitrogen was determined at temperatures between 40 ℃ and 200 ℃ with a heating rate of 20 ℃·min-1,then cooled to 40 ℃ at a rate of 20 ℃·min-1.The sample was heated from 40 ℃ to 200 ℃ at a heating rate of 10 ℃·min-1,held the specimen at 200 ℃ for 10 min,then cooled to 40 ℃ at a rate of 10 ℃·min-1.Results:The melting peak temperature(Tm)of polypropyl-ene infusion bottles was between 145-150 ℃.Conclusion:The proposed method is accurate,sensitive,and sim-ple,and can be used for determination of polypropylene infusion bottles material,which can also provide reference for the standard improvement of polypropylene infusion bottles.