Research on the prediction model of energy expenditure of health Qigong Wuqinxi established by heart rate combined with accelerometer counts
10.3969/j.issn.1000-6710.2024.04.001
- VernacularTitle:心率联合加速度计计数建立健身气功·五禽戏的能量消耗预测模型研究
- Author:
Mingyue LU
1
,
2
;
Longyan YI
;
Shuting YAN
;
Zhihui LU
;
Wei CAO
;
Xiaolei LIU
;
Junqiang QIU
Author Information
1. 北京体育大学(北京 100084)
2. 运动营养北京市高等学校工程研究中心(北京 100084)
- Keywords:
health Qigong Wuqinxi;
energy expenditure;
heart rate;
accelerometer;
prediction model
- From:
Chinese Journal of Sports Medicine
2024;43(4):251-257
- CountryChina
- Language:Chinese
-
Abstract:
Objective To establish the energy expenditure(EE)prediction models of health Qigong Wuqinxi based on heart rate combined with accelerometer counts in different body parts,so to provide a reference for monitoring EE of Wuqinxi.Methods Seventy-four healthy college students aged 18-30 were selected as the research objects.They were divided into a skilled group of 39(21 males and 18 females)and a primary group of 35(17 males and 18 females)according to their level of practice,with 55 in the model group and 19 in the validation group.When performing a set of Wuqinxi,all subjects were recorded heart rate(HR),accelerometer counts[the average counts of X-axis,Y-axis,Z-axis and vector magnitude(VM)],and EE-related indicators by wearing the Polar heart rate moni-tor,ActiGraph-GT3X+accelerometers(9 parts:waist,both arms,both wrists,both thighs,and both ankles)and CORTEX Meta Max3B-R2 portable indirect calorimeter.Based on the accurate EE mea-sured by the gas metabolism meter,linear regression models of only HR,only accelerometer counts,or HR combined accelerometer counts were established,and their accuracy was analyzed and com-pared.Results The EE of Wuqinxi was significantly correlated with gender,height,weight,muscle mass,HR-related indicators,and accelerometer counts in different parts(X-axis counts of the waist,VM values of the left thigh and counts of the X-axis and Y-axis,VM values of the right thigh and the Y-axis,Z-axis count value,left ankle VM value and Y-axis count value,right ankle VM value and Y-axis,Z-axis count value)(P<0.05).Moreover,the adjusted R2 of the prediction model of only HR,only accelerometer counts,and the both were 0.582,0.508 and 0.678,respectively(P<0.05).The correlation between the predicted and measured values ranged between 0.706 and 0.817.Accord-ing to the Bland-Altman analysis,for each model,all except one error value fell outside the 95%confidence interval.That is,all models had an excellent fitting effect and high accuracy.Among them,the combined model was of the best prediction effect:EE(kcal)=-20.089+0.279×body weight(kg)+0.243×ΔHR(exercise HR-quiet HR,bpm)+0.001×Right thigh Y-axis count value+0.181×exer-cise HR(bpm)-4.202×gender(male=0,female=1).Conclusion The EE prediction model of Wuqinxi es-tablished on HR combined with accelerometer counts has the best effect and can calculate the EE more accurately.