The Value of IgG Anti-A/Anti-B Antibody Titers after Absorption of IgG Anti-AB Antibodies in Predicting ABO Fetal Neonatal Hemolytic Disease
10.19746/j.cnki.issn1009-2137.2024.06.041
- VernacularTitle:吸收IgG抗-AB抗体后IgG抗-A/抗-B抗体效价预测ABO-胎儿新生儿溶血病的价值
- Author:
Chen CHENG
1
;
Yi ZHANG
;
Yi-Jing CHEN
;
Qun LUO
;
Hai-Long ZHUO
Author Information
1. 解放军总医院第五医学中心输血医学科,北京 100071
- Keywords:
ABO hemolytic disease of fetus and newborn;
Hyperbilirubinemia of newborn;
IgG anti-AB antibody;
IgG anti-A/anti-B antibody titer
- From:
Journal of Experimental Hematology
2024;32(6):1903-1908
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To analyze the diagnostic value of IgG anti-A/anti-B antibody titer in the serum of type O pregnant women after absorption of IgG anti-AB antibody for ABO hemolytic disease of fetus and newborn (ABO-HDFN).Methods:From February 2020 to September 2020,235 samples of neonatal hemolytic disease whose mother's blood type O from Beijing Blood Center were selected.The titer of IgG anti-A/anti-B antibody in mother's serum before and after absorption of IgG anti-AB antibody was detected by microcolumn gel card,and the incidence of ABO-HDFN was statistically analyzed.The titer level of IgG anti-A/anti-B antibody and the incidence of ABO-HDFN were compared before and after the absorption of IgG anti-AB antibody,and the diagnostic efficacy of the titer level of IgG anti-A/anti-B antibody in the serum of type O pregnant women after the absorption of IgG anti-A and B antibodies on the incidence of ABO-HDFN was analyzed using the receiver's work characteristic (ROC)curve.Results:Of the 235 neonatal hyperbilirubinemia samples with maternal blood type O,127 were blood type A,38 of which were diagnosed as ABO-HDFN;108 were blood type B,of which 31 were diagnosed as ABO-HDFN.Before and after absorption of IgG anti-AB antibody,there was a significant difference in the titer of IgG anti-A/anti-B antibody (P<0.05).Among the 69 confirmed cases,the incidence of ABO-HDFN increased with the increase of IgG anti-A/anti-B antibody with or without the IgG anti-AB antibody,but the anti-A/anti-B antibody titer≥1:512 before the absorption of IgG anti-AB antibody,while the anti-A/anti-B antibody titer decreased significantly,decreasing by three titers,all≤1∶512.The ROC curve shows that the titers of IgG anti-A/anti-B antibodies before and after absorption of IgG anti-AB antibodies can be used as the efficacy indicators for the diagnosis of ABO-HDFN.However,there was a significant difference in the potency of IgG anti-A/anti-B antibody titer for the diagnosis of ABO-HDFN before and after the absorption of IgG anti-AB antibody (P<0.05).The AUC values were greater than before absorption,indicating that the IgG anti-A/anti-B antibody after the absorption of IgG anti-AB antibody was better than before absorption (P<0.05).Conclusion:The higher the titer of IgG anti-A/anti-B antibody measured after absorbing IgG anti-AB antibody,the higher the incidence of ABO-HDFN. In addition,the efficacy of IgG anti-A/anti-B antibody titer to diagnose ABO-HDFN after absorption of IgG anti-AB antibody is higher than that before absorption.