High-frequency ultrasound for measuring thickness of inferior glenohumeral joint capsule
10.13929/j.issn.1672-8475.2024.08.002
- VernacularTitle:高频超声测量盂肱关节下方关节囊厚度
- Author:
Yingxin SU
1
;
Shenyi LI
;
Yi ZHANG
;
Xiangdang LONG
;
Xi LI
;
Mengzhe YANG
;
Yi XIAO
Author Information
1. 湖南师范大学附属第一医院(湖南省人民医院)超声医学科,湖南 长沙 410005
- Keywords:
periarthritis;
shoulder joint;
joint capsule;
ultrasonography
- From:
Chinese Journal of Interventional Imaging and Therapy
2024;21(8):453-456
- CountryChina
- Language:Chinese
-
Abstract:
Objective To observe whether there was difference of inferior glenohumeral joint capsule thickness(ICT)measured on coronal and transverse axillary section with high-frequency ultrasound.Methods ICT of 56 patients with frozen shoulder(FS group)and 115 healthy controls(HC group)were measured on coronal and transverse axillary sections with high-frequency ultrasound.The ultrasonic findings were compared between groups,while ICT measured on different sections were compared within groups.Results In FS group,ICT thickened,presented as low echo with poor boundary clarity,with reduced and uneven internal echo.No echo areas could be detected when there was fluid accumulation,and concomitant blood flow signal could be observed.In HC group,the inferior glenohumeral joint capsule presented as moderate echo with clear boundary,with uniform low or equal echo.No significant difference of ICT values measured on coronal or transverse section was found within both groups(both P>0.05).Conclusion ICT measured on coronal and transverse axillary section with high-frequency ultrasound were not significantly different.