Analysis of total corneal astigmatism and vectors in different regions cen-tered on the corneal apex or pupil
10.13389/j.cnki.rao.2024.0089
- VernacularTitle:以角膜顶点或瞳孔为中心不同区域全角膜散光及矢量的分析
- Author:
Jijiao LIN
1
;
Fuyi LIU
;
Mingming LIU
;
Yaqin JIANG
Author Information
1. 261000 山东省潍坊市,山东第二医科大学(临床医学院)
- Keywords:
cataract;
total corneal astigmatism;
corneal apex;
pupil;
vector analysis
- From:
Recent Advances in Ophthalmology
2024;44(6):458-463
- CountryChina
- Language:Chinese
-
Abstract:
Objective To analyze the differences in total corneal astigmatism(TCA)and vectors in different regions centered on the corneal apex or pupil.Methods This cross-sectional study enrolled 102 patients(102 eyes)with age-re-lated cataracts who underwent phacoemulsification combined with intraocular lens implantation at the Weifang Eye Hospital from October 2021 to June 2022.Before surgery,anterior segment biometrical examinations were performed using Penta-cam to collect the TCA and axes at 2 mm,4 mm,and 6 mm diameter rings and zones with the corneal apex or pupil as the center,and vector analysis was made.Results In the ring mode,a significant difference was observed between the cor-neal apex-centered and pupil-centered astigmatism values for the 6 mm diameter(P<0.05).In the zone mode,there were statistically significant differences between the corneal apex-centered and pupil-centered astigmatism values for the 2 mm,4 mm,and 6 mm diameters(all P<0.05).The analysis of the zone and ring modes centered on the corneal apex showed that there were statistically significant differences in astigmatism values for the 2 mm and 6 mm diameters(both P<0.05).The analysis of the zone and ring modes centered on the pupil showed that there were statistically significant differences in astigmatism values for the 2 mm,4 mm,and 6 mm diameters(all P<0.05).In the same center,there were no statistically significant differences in astigmatism axes for 2 mm,4 mm,and 6 mm diameters under the ring and zone modes(all P>0.05).In the same mode,there were no statistically significant differences in astigmatism axes for 2 mm,4 mm,and 6 mm diameters centered on the corneal apex and pupil(all P>0.05).Vector analysis showed that in the ring mode,the apex-centered to pupil-centered TCA difference of 4 mm on the Y axis was statistically significant(P<0.05).The comparison between the zone and ring centered on the pupil showed that the TCA difference of 4 mm on the Y axis was statistically sig-nificant(P<0.05),whereas the other differences were not statistically significant(all P>0.05).Conclusion The TCA shows a mild difference between the corneal apex-centered and pupil-centered modes and between the ring and zone modes,but the astigmatism axis has no obvious difference.There are some differences between vector analysis and con-ventional analysis of TCA.