Value of multi-slice spiral CT enhanced scanning combined with CT texture analysis in preoperative International Federation of Gynecology and Obstetrics staging of ovarian cancer
10.7683/xxyxyxb.2024.08.014
- VernacularTitle:多层螺旋CT增强扫描联合CT纹理分析在卵巢癌术前国际妇产科联盟分期诊断中的价值
- Author:
Qiang YUE
1
;
Jian'an WEI
;
Shijie LIU
;
Xiaochun HU
Author Information
1. 北京市通州区妇幼保健院放射科,北京 101100
- Keywords:
ovarian cancer;
CT enhanced scanning;
CT texture analysis;
staging diagnosis
- From:
Journal of Xinxiang Medical College
2024;41(8):776-782
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the value of multi-slice spiral CT enhanced scanning combined with CT texture analysis in preoperative International Federation of Gynecology and Obstetrics(FIGO)staging of ovarian cancer.Methods A total of 126 ovarian cancer patients admitted to the Tongzhou District Maternal and Child Health Hospital and Beijing Friendship Hospital,Capital Medical University from March 2021 to September 2023 were selected as the research subjects.All patients underwent multi-slice spiral CT enhanced scanning,and their CT values were measured.Kinetics software was employed for CT texture analysis,and the texture feature-related parameters,including skewness,kurtosis,variance,entropy,and inverse difference,were calculated.The CT values and CT texture feature-related parameters among patients with different FIGO stages were compared.The diagnostic efficacy of CT enhanced scanning,CT texture analysis,and their combination in preoperative FIGO staging of ovarian cancer was evaluated by receiver operating characteristic(ROC)curve,and the consistency between the diagnosis of FIGO stage of ovarian cancer based on CT enhanced scanning,CT texture analysis,and their combination and the pathological diagnosis of FIGO stage of ovarian cancer was evaluated by Cohen's Kappa coefficient analysis.Results The CT value and entropy value of FIGO stage Ⅳ patients were significantly higher than those of FIGO stage Ⅰ,Ⅱ,and Ⅲpatients,and the CT value and entropy value of FIGO stage Ⅲ patients were significantly higher than those of FIGO stage Ⅰand Ⅱ patients(P<0.05);there was no statistically significant difference in the CT value and entropy value between FIGO stage Ⅰ and stage Ⅱ patients(P>0.05).There was no statistically significant difference in skewness,kurtosis,variance,and inverse difference among patients with different FIGO stages(P>0.05).The ROC curve analysis showed that with reference to FIGO stages Ⅰ and Ⅱ,when the cut-off values of CT value and entropy value were 74.645 and 9.540,respectively,the area under the curve(AUC)of CT value and entropy value in diagnosing FIGO stage Ⅲ was 0.733 and 0.743,respectively,the specificity was 0.760 and 0.800,respectively,and the sensitivity was 0.605 and 0.674,respectively;the area under the curve(AUC)of CT value combined with entropy value in diagnosing FIGO stage Ⅲ was 0.818,the specificity was 0.820,and the sensitivity was 0.721.When the cut-off values of CT value and entropy value were 77.095 and 10.020,respectively,the AUC of CT value and entropy value in diagnosing FIGO stage Ⅳ was 0.817 and 0.797,respectively,the specificity was 0.820 and 0.820,respectively,and the sensitivity was 0.545 and 0.667,respectively;the AUC of CT value combined with entropy value in diagnosing FIGO stage Ⅳ was 0.926,the specificity was 0.900,and the sensitivity was 0.758.The consistency between CT enhanced scanning and pathology in diagnosing FIGO stage of ovarian cancer was moderate(Kappa=0.580,P<0.05),with an accuracy rate of 72.22%(91/126);the consistency between CT texture analysis and pathology in diagnosing FIGO stage of ovarian cancer was moderate(Kappa=0.598,P<0.05),with an accuracy rate of 73.81%(93/126);the combination of CT enhanced scanning and CT texture analysis in the diagnosis of FIGO stage of ovarian cancer had a high consistency with pathological diagnosis(Kappa=0.868,P<0.05),with an accuracy rate of 91.27%.Conclusion Multi-slice spiral CT enhanced scanning and CT texture analysis are both reliable methods for the diagnosis of FIGO stage of ovarian cancer.The combination of CT enhanced scanning and CT texture analysis in the diagnosis of FIGO stage of ovarian cancer has a high consistency with pathological diagnosis.The combination of the two can improve the diagnostic efficiency for FIGO stage of ovarian cancer.