CVP in elderly patients with severe diseases: a comparative study of two different measurement approaches
10.3760/cma.j.issn.1674-2907.2017.17.018
- VernacularTitle:两种中心静脉压测量途径在老年重症患者中应用比较
- Author:
Baokun XING
1
,
2
;
Yu SHENG
;
Ying XIA
;
Yan GUI
;
Zhenzhen HU
;
Jinnan GUO
Author Information
1. 100730 中国医学科学院 北京协和医院保健医疗部ICU
2. 100144 北京协和医学院护理学院
- Keywords:
Central venous pressure;
Centrally inserted central catheter;
Peripherally inserted central catheter;
Patients with severe diseases
- From:
Chinese Journal of Modern Nursing
2017;23(17):2270-2275
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the value of central venous pressure (CVP) measured by peripherally inserted central catheters (PICC) and centrally inserted central catheters (CICC) in elderly patients with severe diseases.Methods Paired design and self-controlled was applied in the research. CVP was measured by 2 different measurement approaches in patients with PICC and CICC simultaneously. The sample size was calculated by the enumeration method through the accuracy estimation of consistency evaluation of quantitative measurement, and the required number was 70.Results Among the 70 collected samples, the mean values of the measured CVP by PICC and CICC were (7.995±3.435) cmH2O and (7.743±3.277) cmH2O; no statistically significant difference was observed (t=1.622,P=0.109). The pearson's linear correlation coefficient of the CVP measured by 2 different measurement approaches was 0.926 (P<0.0001). A linear regression model through the origin of the CVP measured by 2 different measurement approaches was fitted with the linear regression equation of CVPPICC=1.023 CVPCICC (R2=0.978); and the 95%CI of the prediction line contained the reference line. The Bland-Altman plot showed that 64 samples fell within limits of agreement (LoA), LoA was -2.300-2.804, with a consistent rate of 91.43%. All the plots out of the LoA did not exceeded the 95%CI.Conclusions The CVP measured by CICC and PICC exhibit high consistency. Therefore, PICC can be used to replace the CICC in the CVP monitoring.