The application value of adaptive statistical iterative reconstruction-Veo combined with full-field organ dose modulation technique in low-dose CT urography
10.3969/j.issn.1002-1671.2024.12.032
- VernacularTitle:自适应统计迭代重建联合全视野器官剂量调制技术在低剂量CT尿路成像中的应用价值
- Author:
Qiye CHENG
1
;
Yijun LIU
;
Xiaoyu TONG
;
Shigeng WANG
;
Yong FAN
;
Anliang CHEN
;
Mengting HU
;
Jingyi ZHANG
Author Information
1. 大连医科大学附属第一医院放射科,辽宁 大连 116011
- Keywords:
computed tomography urography;
organ dose modulation technique;
radiation dose;
adaptive statistical iterative reconstruction-Veo
- From:
Journal of Practical Radiology
2024;40(12):2071-2075
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the clinical application value of posterior adaptive statistical iterative reconstruction-Veo(ASIR-V)algorithm combined with full-field organ dose modulation(ODM)technique in low-dose computed tomography urography(CTU).Methods Ninety patients who underwent urological contrast-enhanced and CTU examination were prospectively selected and divided into conventional dose group(group A,NI=11,posterior ASIR-V of 60%),low-dose group(group B,NI=15,posterior ASIR-V of 60%-100%with 10%interval,denoted as B1-B5 groups);full-field ODM low-dose group(group C,NI=15,posterior ASIR-V of 60%-100%with 10%interval,denoted as C1-C5 groups)according to the noise index(NI).The volume rendering(VR)and maximum intensity projection(MIP)images were reconstructed.The CT values and standard deviation(SD)values of the renal cortex and para-spinal muscles were measured,and the signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)were cal-culated.The CT values of the renal pelvis,ureter,and bladder were measured,and the SNR and CNR were calculated with the para-spinal muscles as background.The subjective score was performed on the two-dimensional and three-dimensional images to evaluate the ability of CTU to display lesions.The volume CT dose index(CTDIvol),dose length product(DLP),and effective dose(ED)of the three groups were compared.Results The bladder SNR and CNR of groups B1,C1,and C2 were lower than those of group A(P<0.05).There was no statistically significant difference in the SNR and CNR of each tissue between groups B2,C3 and group A(P>0.05).The SNR and CNR of each tissue in groups B4,B5,and C5 were higher than those in group A(P<0.05).The display rate of lesions in urinary system in groups B2 and C3 could reach 100%.There was no statistically significant difference in the axial image scores between groups B2,C3 and group A(P>0.05),while the VR and MIP image scores in each group were comparable to those in group A(P>0.05).The CTDIvol of groups A,B and C were(6.08±2.11)mGy,(3.15±1.15)mGy,and(2.9±0.92)mGy,respectively.Conclusion CTU using the full-field ODM technique combined with posterior 80%ASIR-V can reduce the CTDIvol by 52.30%,and further reduce by 7.93%compared with group B,which is effective to reduce radiation to the gonads.