Optimization of low-dose deep inferior epigastric artery CT angiography parameters based on deep learning image reconstruction algorithm
10.3969/j.issn.1002-1671.2024.07.032
- VernacularTitle:基于深度学习图像重建算法优化低剂量腹壁下动脉CT血管成像参数
- Author:
Mengting HU
1
;
Yijun LIU
;
Shigeng WANG
;
Xiaoyu TONG
;
Yong FAN
;
Anliang CHEN
;
Jingyi ZHANG
;
Qiye CHENG
Author Information
1. 大连医科大学附属第一医院放射科,辽宁 大连 116011
- Keywords:
deep inferior epigastric artery;
computed tomography;
deep learning image reconstruction
- From:
Journal of Practical Radiology
2024;40(7):1179-1183
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the application value of deep learning image reconstruction(DLIR)algorithm in low-dose deep inferior epigastric artery(DIEA)computed tomography angiography(CTA).Methods A total of 59 patients undergoing DIEA CTA were prospectively selected and randomly divided into two groups:group A(29 cases)and group B(30 cases).Group A was the conventional radiation dose group(tube voltage 120 kVp),the tube current was dose modulation 3,and the iterative reconstruction algo-rithm was Karl 5.Group B was the low radiation dose group(tube voltage 120 kVp),the tube current was dose modulation 2,with DLIR reconstruction algorithm,and four levels of DLIR(1-4)were reconstructed and labeled as groups B1 to B4.The mean tube current,vol-ume CT dose index(CTDIvol),and dose length product(DLP)of group A and group B were recorded,and the effective dose(ED)was calculated.The CT and standard deviation(SD)values of the external iliac artery and psoas major muscle were measured on axial images of each group,and signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)were calculated.Two observers using double-blind method independently evaluated the DIEA on volume rendering(VR)and maximum intensity projection(MIP)images of each group using a 3-point scale,and a 5-point scale was used to evaluate the overall image quality on axial images.Results Compared with group A,the mean tube current and ED in group B were decreased by 39.33%and 44.09%,respectively(P<0.05).With the increasing of DLIR level from groups B1 to B4,the SD value of the image gradually decreased,while SNR and CNR gradually increased(P<0.05).The CNR in groups B3 and B4 was higher than that in group A(P<0.05).The subjective scores of the two observers were consistent(Kappa value 0.779-0.889,P<0.05),and there was no statistical significance between group A and group B in the perforating vessels from the DIEA,intramuscular course,and the point of emergence(P>0.05).With the increase in DLIR level,the subjective score of the overall image quality from group B1 to group B4 showed a trend of first increasing and then decreasing,and the score of group B3 was the highest(4.50±0.51)points,which had no statistical significance compared with group A(4.45±0.51)points(P>0.05).Conclusion DLIR can effectively reduce the radiation dose of the DIEA CT A scan and ensure the image quality,among which DLIR 3 is the recommended best reconstruction grade.