Management of CT radiation dose in radiology department via applying Six Sigma management method
10.3969/j.issn.1002-1671.2024.07.029
- VernacularTitle:应用六西格玛管理法对放射科CT辐射剂量的管理
- Author:
Haijing QIU
1
;
Jiayi DU
;
Tianlai LI
;
Zhigang JI
;
Qi PAN
;
Ning WANG
;
Chunhai LUO
Author Information
1. 西安医学院第二附属医院影像科,陕西 西安 710038
- Keywords:
Six Sigma;
computed tomography;
radiation dose;
quality management
- From:
Journal of Practical Radiology
2024;40(7):1165-1169
- CountryChina
- Language:Chinese
-
Abstract:
Objective To enhance CT radiation dose management in radiology department via applying Six Sigma management method.Methods The radiation quality control processes in the radiology department were optimized according to the Six Sigma quality management DMAIC pattern.The volume CT dose index(CTDIvol),dose length product(DLP),radiation quality control problems of adult and pediatric CT scans from January 2022 to February 2022 were collected as baseline data,and data collected from August 2022 to September 2022 were taken as the control group for analysis via Six Sigma management method.All data of the dose values and problem rates were compared and analyzed between before and after Six Sigma management methods.Results The DLP in the adult group was decreased by 65.5%in computed tomography urography(CTU),decreased by 25.5%in neck enhancement,decreased by 9.8%in head,decreased by 24%in facial cranial,and decreased by 27.7%in chest enhancement,with a statistical difference(P<0.05).While DLP in the adult group was decreased by 9.7%in abdominal enhancement,with no significant difference(P>0.05).The DLP in the pediatric(<1 year)group was increased by 35%in head scans,with no significant difference(P>0.05).While the DLP was decreased by 30.2%in 1 to 5 years group,decreased by 21.8%in 6 to 10 years group,decreased by 27.6%in 11 to 15 years group,with statistical difference(P<0.05).The DLP of facial cranial was decreased by 43.3%in 6 to 10 years group,decreased by 29.1%in 11 to 15 years group,with statistical difference(P<0.05).The DLP of chest was decreased by 13%in<1 year group(P>0.05),increased by 2.2%in 1 to 5 years group(P>0.05),decreased by 42.6%in 6 to 10 years group,decreased by 54.2%in 11 to 15 years group(P<0.05).The incidence of radiological quality control problems of after Six Sigma management was significantly lower than that of before Six Sigma management(P<0.05).Conclusion Six Sigma management method can identify problems in the clinical practice and enhance the ability of radiation quality control through optimization.