Effect observation of stat lock device applied in fixing implantable venous access port of butterfly wing without injury needle
10.3760/cma.j.issn.1674-2907.2016.22.039
- VernacularTitle:思乐扣装置固定植入式静脉输液港蝶翼无损伤针的效果观察
- Author:
Lixia YUE
1
;
Mei GUO
;
Shuhao ZHANG
Author Information
1. 100853 北京,解放军总医院肿瘤内一科
- Keywords:
Stat lock;
Implantable venous access port;
Butterfly needles
- From:
Chinese Journal of Modern Nursing
2016;22(22):3247-3248,3249
- CountryChina
- Language:Chinese
-
Abstract:
Objective To observe the application effect of stat lock device on fixing butterfly needles. Methods A total of 124 patients with implantable venous access port and venous chemotherapy from our hospital were selected by cluster sampling during April 2015 to July 2015. According to the odd and even-numbered day grouping method, all patients were divided into control group(64 patients) and experimental group(60 patients). Patients in experimental group use stat lock and transparent dressing fixing butterfly needles, and patients in control group use sterile gauze and transparent dressing fixing butterfly needles, statistical cases of comfort changing and drop speed slower and repeated puncture of two groups were compared. Results The comfort of patients fixed butterfly needles in control group were lower than those in experimental group(P<0.01), but the drop speed and repeated puncture in experimental group were lower than those in control group ( P<0. 05 ) . Conclusions The method of stat lock fixing butterfly needles can effectively improve the comfort of patients and cut down the drop speed and repeated puncture, which is suitable for widespread clinical application.