Influence of different ROI sketch on measurement results in the diagnosis of breast cancer by imaging technology of IVIM
10.3760/cma.j.cn115807-20230718-00007
- VernacularTitle:IVIM成像技术诊断乳腺癌中ROI勾画方式对测量结果的影响
- Author:
Jin ZHOU
1
;
Haipeng GONG
;
Hongyi DING
;
Yu LIU
Author Information
1. 南通市肿瘤医院 南通大学附属肿瘤医院影像科,南通 226001
- Keywords:
Intravoxel incoherent motion imaging;
Breast cancer;
Region of interest
- From:
Chinese Journal of Endocrine Surgery
2024;18(5):634-637
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To study the influence of different region of interest (ROI) sketch on measurement results in the diagnosis of breast cancer by imaging technology of intravoxel incoherent motion (IVIM) .Methods:The clinical dataes of 84 patients with breast mass lesions from Apr. 2017 to Oct. 2021 were collected, all patients underwent IVIM-DWI. ROI was delineated at the maximum level of the mass by tumor contour method and fixed radius method. The apparent diffusion coefficient (ADC), real diffusion coefficient (D), perfusion fraction (f) and pseudo diffusion coefficient (D *) were recorded. IVIM-DWI parameters of patients with benign and malignant breast tumors were compared. The influence of ROI delineation by tumor contour method and fixed radius method on the results of IVIM related parameters were compared. Results:Forty-six of 84 patients were malignant and 38 benign masses. The ADC and D values of patients in the malignant group were (0.98±0.24) ×10 -3 mm 2/s, (0.79±0.22) ×10 -3 mm 2/s in the malignant group, significantly lower than those in the benign group [ (1.65±0.43) ×10 -3 mm 2/s, (1.41±0.35) ×10 -3 mm 2/s], and the f value and D * value were (5.65±1.13) %, (43.89±8.05) ×10 -3 mm 2/s, significantly higher than those in the benign group [ (3.84±1.57) %, (37.77±9.3) ×10 -3 mm 2/s]. The differences were statistically significant ( t=9.01, 9.89, 6.13, 3.23; all P<0.05). The results obtained by using the tumor fixed radius method to delineate ROI showed that the ADC and D values of (0.96±0.27) ×10 -3 mm 2/s (0.81±0.23) ×10 -3 mm 2/s in the malignant group were significantly lower than those in the benign group [ (1.66±0.39) ×10 -3 mm 2/s, 1.39±0.37) ×10 -3 mm 2/s], and the f and D * values were (5.69±1.15) %, (43.94±7.98) ×10 -3 mm 2/s, which were significantly higher than those in the benign group [ (3.86±1.49) %, (38.01±8.46) ×10 -3 mm 2/s]. The differences were statistically significant ( t=9.69, 8.78, 6.35, 3.30; all P<0.05) .The 95% consistency interval range of ADC difference, D value difference, f value difference, and D * value difference obtained by using tumor contour method to delineate ROI was smaller than that of tumor fixed radius method. Conclusions:The IVIM has high accuracy in the diagnosis of breast cancer, the IVIM parameters obtained from ROI delineation by tumor contour method have good repeatability.