A new robot-assisted puncture system used for CT-guided lung puncture biopsy:its application research and nursing cooperation
10.3969/j.issn.1008-794X.2024.05.016
- VernacularTitle:新型机器人辅助穿刺系统在CT引导下肺穿刺活检术的应用研究及护理配合
- Author:
Zheng ZHANG
1
;
Xiaolu YU
;
Fei LI
;
Jian KANG
;
Xiaojia TANG
;
Yijun LU
Author Information
1. 200433 上海 同济大学附属上海市肺科医院放射科
- Keywords:
CT-guided lung puncture;
robot-assisted puncture system;
positioning accuracy;
satisfaction with nursing;
complication of lung puncture;
nursing
- From:
Journal of Interventional Radiology
2024;33(5):549-553
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the clinical effect and nursing cooperation of the new robot-assisted puncture system RC120 in CT-guided lung puncture biopsy,so as to provide practical basis for the promotion and utilization of the new robot-assisted puncture system.Methods Using random sampling method,a total of 29 patients,who received robot-assisted lung puncture at the Shanghai Municipal Pulmonary Hospital of China between January and June of 2022,were collected as the study group,while other 29 patients,who received traditional manual lung puncture under CT guidance in the same period,were collected as the control group.For the patients of the control group traditional nursing was implemented,while for the patients of the study group on the basis of traditional nursing the additional targeted nursing care was carried out.The accuracy of puncture localization,satisfaction with the nursing care,and incidence of complications were compared between the two groups.Results The accuracy of puncture localization in the study group was 5.0 mm(3.6-6.2 mum),which was better than 6.4 mm(4.0-8.4 mm)in the control group,and the difference was statistically significant(Z=-2.179,P=0.034).The patient satisfaction score in the study group was(91.1±1.6)points,which was significantly higher than(82.2±1.7)points in control group,and the difference was statistically significant(t=21.047,P<0.001).In the study group 2 patients developed complications with an incidence of 6.9%,while in the control group 8 patients developed complications with an incidence of 27.6%,and the difference was statistically significant(x2=4.350,P=0.037).Conclusion The implementation of targeted nursing care can reduce the risk of complications caused by CT-guided lung puncture with RC120 auxiliary puncture system,improve the accuracy of puncture localization,and improve patient satisfaction with nursing care,therefore,the targeted nursing care deserves promotion in clinical practice.(J Intervent Radiol,2024,33:549-553)