Effects of different side tension pneumothorax on hemodynamic in pigs
10.11855/j.issn.0577-7402.0229.2024.0530
- VernacularTitle:不同侧张力性气胸对猪血流动力学的影响
- Author:
He-Shan HUANG
1
;
Peng-Fei LIU
;
Meng-Jie DOU
;
Si-Yu CHEN
;
Fa-Qin LYU
;
Wei CHEN
Author Information
1. 解放军医学院,北京 100853
- Keywords:
tension pneumothorax;
animal model;
autonomous respiration;
hemodynamics
- From:
Medical Journal of Chinese People's Liberation Army
2024;49(8):897-904
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the effects of different side tension pneumothorax on hemodynamics in pigs,providing data support for the optimization of on-site first-aid procedures for pneumothorax.Methods Twelve Bama pigs were randomly divided into left-sided tension pneumothorax group and right-sided tension pneumothorax group(6 in each group).During the occurrence of pneumothorax and as the pleural pressure gradually increases by 1 mmHg increments,the key indicators were collected using pulse indicator continuous cardiac output(PICCO)technology:hemodynamic indicators[global ejection fraction(GEF),cardiac output(CO),global end-diastolic volume(GEDV),intrathoracic blood volume(ITBV),stroke volume(SV),mean arterial pressure(MAP)],basic vital signs[heart rate(HR),diastolic blood pressure(DBP),systolic blood pressure(SBP)],and arterial blood gas parameters[partial pressure of oxygen(PO2),partial pressure of carbon dioxide(PCO2)].Mediastinal localization was subsequently performed using radiographs.Differences were investigated through comparison between the two groups and within each group before and after the procedure.Results By comparing the hemodynamic changes and X-ray examination results,twelve Bama pigs tension pneumothorax models were successfully constructed.Hemodynamic analysis showed that in left-sided tension pneumothorax model when the pleural pressure reached 8 mmHg,SBP,DBP,MAP,CO,GEF,SV,GEDV and ITBV were significantly lower than those during the occurrence of ipsilateral pneumothorax(P<0.05).In right-sided tension pneumothorax model,when the pleural pressure reached about 3 mmHg,SBP,DBP,MAP,SV,GEDV,and ITBV were significantly lower than those during the occurrence of ipsilateral pneumothorax(P<0.05).Blood gas analysis showed that at 8 mmHg for left-sided and 3 mmHg for right-sided tension pneumothorax,compared with the occurrence of their respective ipsilateral pneumothorax,PO2 was significantly lower(P<0.05)and PCO2 was significantly higher(P<0.05).Conclusions There are different effects on hemodynamics in different side tension pneumothorax.Compared with left tension pneumothorax,right tension pneumothorax can lead to serious consequences under a smaller pleural pressure.Different side tension pneumothorax models can be constructed according to the actual situation when performing pneumothorax related experiments.