Study on quality analysis of Lonicera alberti Regel. Leaves by QAMS
10.3760/cma.j.cn115398-20240402-00024
- VernacularTitle:一测多评法对沼生忍冬叶质量分析研究
- Author:
Yan CHEN
1
;
Huijing HAN
;
Yuhan YAO
;
Jun ZHAO
;
Fang XU
;
Chenyang LI
Author Information
1. 新疆维吾尔自治区药物研究所植物化学研究室 新疆维吾尔自治区维吾尔药重点实验室,乌鲁木齐 830011
- Keywords:
Honeysuckle Leaf;
Quantitativeanalysis of multi-components with a single-marker;
Relative correction factors;
Assay (TCD);
Quality contral
- From:
International Journal of Traditional Chinese Medicine
2024;46(12):1629-1635
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To establish the QAMS method for content determination of eight chemical compositions (chlorogenic acid, neochlorogenic acid, cryptochlorogenin acid, isochlorogenic acid A, isochlorogenic acid C, rutin, morroniside and luteolin-7-O-glucoside) from Lonicera alberti Regel. leaves; To verify the feasibility and applicability of this method in quality control for Lonicera alberti Regel. leaves. Methods:The HPLC analysis was performed on a Agilent Eclipse XDB-C18 (250 mm×4.6 mm,5 μm) with a mobile phase consisted of acetonitrile and 0.1% formic acid solution in gradient elution manner at a flow rate of 1 ml/min. The column temperature was maintained at 30 ℃ and the detection wavelength was set at 258 nm. The injection volume was 10 μl.Results:Chlorogenic acid, neochlorogenic acid, cryptochlorogenin acid, isochlorogenic acid A, isochlorogenic acid C, rutin, morroniside and luteolin-7-O-glucoside had a good linear relationship in the corresponding concentration range ( r≥0.999 6). The average sample recovery rates were 103.16%, 103.98%, 99.49%, 103.78%, 102.74%, 101.12%, 104.62%, and 100.94%, respectively. The RSD values were 1.30%, 1.63%, 2.92%, 2.10%, 1.27%, 2.40%, 1.15%, and 2.76%, respectively. Chlorogenic acid was set as internal reference substance, the relative correction factors of isochlorogenic acid A, isochlorogenic acid C, neochlorogenic acid, cryptochlorogenin acid, morroniside, luteolin-7-O-glucoside, rutin were 0.785 5, 0.693 9, 1.001 5, 1.087 2, 1.233 9, 0.369 1, 0.507 5, respectively. The content determination results of QAMS method and external standard method showed that there was no statistical significance in the comparison of the other six components except for morroniside. Conclusions:The established HPLC method can be used for the quality control of Lonicera alberti Regel. leaves. QAMS can be used to determine the contents of neochlorogenic acid, cryptochlorogenic acid, isochlorogenic acid A, isochlorogenic acid C, rutin and luteolin-7-O-glucoside in Lonicera alberti Regel. leaves.