Literature analysis of finite element model and material characteristics of cervical vertebra
10.3760/cma.j.cn121382-20240420-00508
- VernacularTitle:颈椎有限元模型及材料特征的文献分析
- Author:
Bifeng FU
1
;
Xingyu JIANG
;
Chao ZHANG
;
Jin SU
;
Guang YANG
;
Aifeng LIU
;
Yuping GAO
;
Ping WANG
;
Yuandong LI
Author Information
1. 天津中医药大学第一附属医院骨伤科,国家中医针灸临床医学研究中心,国家中医药管理局区域中医骨伤科诊疗中心,天津 300381
- Keywords:
Cervical vertebra;
Finite element model;
Material characteristics;
Literature analysis
- From:
International Journal of Biomedical Engineering
2024;47(5):463-471
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To provide references for the application of finite element model in the study of cervical vertebra by statistically analysing the frequency, numerical value, properties, and boundary setting of the finite element model and the corresponding material features as well as boundary settings in the literature.Methods:The literature on cervical vertebra-related finite element models was collected from CNKI, Wanfang, VIP, PubMed, Web of Science, and Embase databases from January 2013 to December 2023. The quality assessment was followed by manual screening. The data sources, application classification, material properties (Young’s modulus and Poisson’s ratio), and boundary conditions of cervical vertebra, cervical intervertebral, and cervical ligaments were statistically analyzed.Results:A total of 102 papers were included. The finite element models of the cervical vertebra were derived from medical image reconstruction modeling techniques, predominantly CT plain scan and magnetic resonance imaging. Among the 102 cervical vertebra models, the C3-C7 (lower cervical segment) model appeared with the highest frequency (19). The Young’s modulus of the cortical bone, cancellous bone, and posterior structure of cervical vertebrae were set at about 12 000 or 10 000, 440, and 3 600 MPa, respectively, and the Poisson’s ratios were mainly set at about 0.29 or 0.30, 0.29, and 0.29. The Young’s modulus of the cervical intervertebral disc endplate, nucleus pulposus, and annulus fibrosus were concentrated around 500 or 2 000, 1, and 100 MPa, respectively, and the Poisson’s ratios were set at about 0.40, 0.50, and 0.40, respectively. The Young’s modulus of the anterior longitudinal ligament, posterior longitudinal ligament, transverse ligament, ligamentum flavum, interspinous ligament, capsular ligament, and articular cartilage of the cervical spine were set around 30, 20, 20, 6-10, 4-8, 10 or 20, 10 MPa, and the Poisson’s ratios were set at aoubt 0.30, 0.30, 0.30, 0.30, 0.30, 0.40, and 0.30, respectively. The Young’s modulus of the upper cervical interdental ligament, lamina, cruciate ligament, nuchal ligament, and pterygoid ligament were set at about 10, 10, 10 or 20, 20, and 5 MPa, respectively, and the Poisson’s ratios were set at about 0.30. Head weight settings were more common at 50, 74, and 100 N.Conclusions:The finite element model of the cervical vertebra has great value in the study of cervical spondylosis, but further optimization is still needed in the assignment of material properties, mesh division, and model verification to improve the accuracy and clinical applicability of the model.