Study of micro-guide wire application in the PICC malposition
10.3760/cma.j.issn.1674-2907.2012.14.016
- VernacularTitle:介入微导丝应用于PICC导管异位复位中的效果
- Author:
Hai-Li GUAN
1
;
Ping DONG
;
Lin-Lin CAO
;
Yong-Fang GU
;
Xiang-Ju WU
Author Information
1. 徐州市第一人民医院
- Keywords:
Micro-guide;
PICC;
Catheter ectopic;
Reset
- From:
Chinese Journal of Modern Nursing
2012;18(14):1659-1661
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the application of the involvement of micro-guide wire in the peripherally inserted central catheter (PICC) ectopic reset.Methods Totals of 74 patients with PICC ectopic were divided into experimental group and control group,and each group included 37 cases.The experimental group reset ectopie PICC through placing micro-guide wire under the guidance of digital subtraction angiography,while control group adjusted patient position and sent catheter according to conventional methods.The success rate of a reset,the operating time,the incidence of mechanical phlebitis were observed.Results The success rate of a reset in experimental group and control group were 100% and 83.88%,respectively.The operation time during reset procedure were 4 min and 5 min in experimental and control group,respectively.Regarding the incidence of mechanical phlebitis due to reset,2.7% in experimental group and 21.62% in control group,there were statistical differences in three observational indexes( x2 =6.529,7.400,respectively;Z =-1.989;P < 0.05 or P <0.01 ).Conclusions The involvement of micro-guide wire in the PICC ectopic adjustment can reduce the incidence of mechanical phlebitis and have a high reduction ratio.