Analysis on positioning errors and adverse reactions of breast cancer
10.3969/j.issn.1671-8348.2024.22.019
- VernacularTitle:乳腺癌摆位误差及不良反应分析
- Author:
Tingting TANG
1
;
Yong ZHONG
;
Ping TANG
;
Lin HU
;
Xuerui ZHENG
;
Chuan CHEN
Author Information
1. 陆军军医大学大坪医院肿瘤科,重庆 400042
- Keywords:
breast cancer;
radiation therapy;
positioning error;
cone beam CT;
precision radiotherapy
- From:
Chongqing Medicine
2024;53(22):3469-3472
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the factors influencing the positioning error of conical beam CT(CBCT)radiotherapy and the occurrence of acute radiation dermatitis in breast cancer fixed by cervical and thoracic integrated membrane in order to provide a basis for personalized out-target external boundary,selec-tion of fixed mode and guidance of radiodermatitis clinical practice work.Methods A total of 147 patients with breast cancer in this hospital from June 2022 to October 2023 were selected as the study subjects,inclu-ding 74 cases of breast conserving operation and 73 cases of modified radical(excision)operation.During the treatment period,CBCT scanning once a week obtained the image and conducted the grey match with the planned CT images to acquire the translational error of X(left and right),Y(head and foot)and Z(abdominal and dorsal)and the rotational posing error of X(pitch),Y(roll)and Z(yaw)axis,and at the same time,the acute radiodermatitis in nearly 3 months during radiotherapeutic period was recorded.Results Compared with the Z axis,the translation error of X axis and Y axis was greater,the rotation error was smaller,and the differ-ences were statistically significant(P<0.05).The PTV external boundary of X,Y and Z axis calculated by the formula was 0.70,0.76,0.46 cm respectively.There was no statistically significant difference in the posi-tioning error of each direction of left and right breast between breast conservation operation and breast resec-tion operation(P>0.05).The correlation between the age with X,Y and Z axis translation errors was-0.14,0.18 and 0.10 respectively,which of the age with X,Y and Z axis rotation errors was 0.12,<0.01,0.02 respectively.The occurrence of grade 1 acute radiodermatitis in the patients with breast conserving oper-ation was 100.0%(74/74),which in the patients with excision operation was 13.7%(10/73),the occurrence of grade 2 was 82.2%,which of grade 3 was 4.1%(3/73),and the difference between them was statistically significant(P<0.05).Conclusion In the every day positioning and target area external expansion,particular attention should be paid to the X and Y axis translational directions and the Z axis rotation direction.Using the integrated cervicothoracic thermoplastic membrane for fixing breast cancer is not affected by the operation mode,affected side position and age.