Objective To investigate the safe time of sterile equipments used in laminar flow operating room.Methods In ten operations ( Class Ⅰ ) which last 8 or more hours,we sampled preoperative air,surgery equipments 4 h,6 h,8 h pre and intra-operatively,and surgical personnel' s hands for bacterial culture.Results There was no growth of bacteria in the sampling of preoperative air,surgical personnel's hands and surgical instruments during operation,pass rate was 100%.Conclusions The sterile equipments used in the same operation could be used safely for 8 hours in operating room where the condition of Level 100 laminar flow reached.