Research on improved dispensing technology to reduce infusion particle pollution and raise infusion security
10.3760/cma.j.issn.1674-2907.2011.10.041
- VernacularTitle:改良配药技术对减少输液微粒污染提高输液安全性的研究
- Author:
Mei-Fang XU
1
;
Hui-Rong YANG
;
Yan BAI
;
Rui-Zhi RU
;
Li-Zhu LIANG
Author Information
1. 深圳市宝安区沙井人民医院
- Keywords:
Dispensing method;
Particles;
Pollution;
Transfusion safety
- From:
Chinese Journal of Modern Nursing
2011;17(10):1215-1217
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the optimal method of dispensing safety, and increase work efficacy. Methods The experimental group and control group were collected with 30 cases respectively. The control group was treated with conventional dispensing methods, experimental group improved dispensing method. The number of insoluble particles was observed between the two groups. Results The experimental group showed ≥ 10 microns (a/ml), and ≥ 25 microns (a/ml) than in the control group (P < 0. 01), but both failed to meet the standards of the Chinese Pharmacopoeia. Conclusions The modified method can reduce the transfusion of dispensing particulate pollution, but the establishment of intravenous infusion center or install clean benches pharmacy dispensing is necessary.