Application of energy metabolic car in artificial airway patients in ICU
10.7619/jcmp.201810012
- VernacularTitle:能量代谢车在ICU人工气道患者中的应用
- Author:
Jingye ZHAN
1
;
Juan LU
;
Pengcheng LIU
Author Information
1. 苏州大学附属第二医院ICU创伤单元
- Keywords:
energy metabolism car;
ICU patients;
artificial airway;
nursing
- From:
Journal of Clinical Medicine in Practice
2018;22(10):41-43
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the energy metabolism of artificial airway patients in ICU.Methods The energy metabolism rate of ICU patients with artificial airway was measured by energy metabolism car and compared with the energy metabolism calculated by HB formula.Results The energy metabolism value of ICU patients with artificial airway was (1 831.07 ± 301.12) kcal measured by energy metabolism car,and the energy metabolism value calculated by HB formula was (2 126.03 ±411.05) kcal,which showed a significant difference (P <0.01).Conclusion The energy metabolism car can more accurately monitor the energy metabolism of ICU patients with artificial airway,and provide better nutrition treatment for the patients.