Closed-loop Blood Transfusion Management System Based on PDA
10.3969/j.issn.1671-7104.2013.05.020
- VernacularTitle:基于PDA的闭环式输血管理系统
- Author:
Yiyi CHEN
1
;
Canda CHEN
;
Luo LUO
;
Zhou YIN
;
Min ZHOU
;
Qiong XIE
;
Min XU
;
Qiutao ZHANG
Author Information
1. 浙江大学医学院附属第一医院
- Keywords:
closed-loop management;
blood transfusion management system;
mobile nursing
- From:
Chinese Journal of Medical Instrumentation
2013;(5):376-378
- CountryChina
- Language:Chinese
-
Abstract:
A closed-loop transfusion management system is constructed that covers blood preservation, transportation, transfer, distribution of blood, distribution, clinical blood specimen col ection and blood transfusion process, which can monitor the implementation of doctor's advice, view the transport process of blood and blood samples, and record blood transfusion and adverse reaction information. These measurements can play a good effect in reduction of manual records and handover links in blood transfusion management, enhance the blood bank management, guarantee safely using blood, and realize the goal of real-time monitoring and closed-loop management.