Influence of two positions for measuring instrument adapter on measurement of hand-transmitted vibration in grinding machine
10.3760/cma.j.issn.1001-9391.2016.06.006
- VernacularTitle:两种测量仪适配器佩戴位置对砂轮机手传振动测量的影响
- Author:
Xiaoshuang XIE
1
;
Min ZHANG
;
Yingdong ZHENG
;
Xieyi DU
;
Cheng QI
Author Information
1. 中国疾病预防控制中心职业卫生与中毒控制所
- Keywords:
Vibration;
Hand-transmitted vibration;
Measurement;
Intraclass correlation coefficient
- From:
Chinese Journal of Industrial Hygiene and Occupational Diseases
2016;34(6):426-429
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the influence of two positions for measuring instrument adapter on the measurement of hand-transmitted vibration in grinding machine using the intraclass correlation coefficient (ICC) of reliability assessment index,and to provide a basis for studies on the measurement standard for handtransmitted vibration.Methods With reference to the measurement standard for hand-transmitted vibration ISO 5349 Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted vibration-Part 1:General requirements and Mechanical vibration-Measurement and evaluation of human exposure to handtransmitted vibration-Part 2:Practical guidance for measurement at the workplace,the domestic AWA5936 hand-transmitted vibration measuring instrument and SVAN-106 hand-transmitted vibration measuring instrument from Poland were used to measure hand-transmitted vibration in 3 workers for grinding machine in a foundry for 5 days continuously from September to October,2014,and Y-axis data were recorded and compared.Results In worker A,the "T"-shaped adapter had a significantly higher mean Y-axis accelerated speed effective value than the "O"-shaped adapter [4.34 m/s2 (95%CI 4.05-4.63) vs 2.32 m/s2 (95%CI 2.27~2.38),t=13.781,P<0.01]-In workers B and C,AWA5936 "U"-shaped adapter (placed at the position of the handle of grinding machine) had lower degrees of data variation of 12.55% and 15.77%,respectively,suggesting good data stability.The measurement results showed significant differences across different positions of adapter(P<0.01) and between all adapters except "O"-shaped and line-shaped adapters (all P<0.01),while the measurement results showed no significant differences between the"O"-shaped and line-shaped adapters (P>0.01).The comparison of the measurement results of AWA5936 vibration measuring instrument with an "U"-shaped adapter and SVAN-106 vibration measuring instrument with an "S"-shaped adapter showed an ICC of >0.80 (ICC=0.82),while the comparison of the measurement results of AWA5936 vibration measuring instrument with an "O"-shaped adapter and SVAN-106 vibration measuring instrument showed an ICC of <0.40.Conclusion SVAN-106 vibration measuring instrument with an "S"-shaped adapter placed at the palm and AWA5936 vibration measuring instrument with an"U"-shaped adapter placed at the handle of grinding machine can give comparable measurement results with good reliability.