Application of immuno-rotary biosensor based on F0F1 -ATPase in chromatophores for detecting HIV-1 P24
10.3760/cma.j.issn.1003-9279.2010.04.022
- VernacularTitle:免疫旋转生物传感器高灵敏检测HIV-1 P24抗原方法的研究
- Author:
Yun-Hu SANG
1
;
Xiao-Mei ZHANG
;
Xiao-Guang ZHANG
;
Jing MA
;
Xue-Ren LI
;
Jia-Chang YUE
;
Yi ZENG
Author Information
1. 北京工业大学
- Keywords:
HIV;
Immuno-rotary biosensor;
ATP synthetase complexes
- From:
Chinese Journal of Experimental and Clinical Virology
2010;24(4):305-307
- CountryChina
- Language:Chinese
-
Abstract:
Objective To build a high sensitive method to detect HIV-1 P24 antigen quantitatively by Immuno-rotary Biosensor (IRB) based on F0F1-ATPase. Methods The immuno-rotary biosensor based on F0F1-ATPase in chromatophores for detecting HIV-1 P24 was assembled by label F0F1-ATPase chromatophores with the biotin-labled HIV-1 P24 antibody through the streptavidin-biotin-β antibody and the pH sensitivity of fluorescence F1300. Then it's sensitivity and specificity was tested by the prokaryotic expressed HIV-1 P24 antigen. Results Immuno-rotary biosensor based on F0F1-ATPase in chromatophores can detect P24 antigen sensitivily, the lowest level that could be detected was 0.1 fg/ml. Conclusion IRBbased system was successfully assembled and used for the detection of P24 antigen, the rapid and sensitive technique will be useful for detecting HIV-1 P24 antigen quantitatively.