Clinical application of a prefabricated interocclusal recording cap for making interocclusal records of implant-supported fixed prostheses
10.3760/cma.j.cn112144-20210923-00424
- VernacularTitle:预成咬合记录帽制取种植固定修复咬合记录的临床应用研究
- Author:
Qian DING
1
;
Tingting PU
;
Mingzhu HE
;
Shimin WANG
;
Wenjin LI
;
Lei ZHANG
;
Jianzhang LIU
;
Dai TONG
;
Yongsheng ZHOU
Author Information
1. 北京大学口腔医学院·口腔医院修复科 国家口腔医学中心 国家口腔疾病临床医学研究中心 口腔数字化医疗技术和材料国家工程实验室 口腔数字医学北京市重点实验室 100081
- Keywords:
Dental implantation;
Dental prosthesis;
Jaw relation record;
Implant-supported fixed prosthesis;
Prefabricated interocclusal recording cap;
Accuracy
- From:
Chinese Journal of Stomatology
2021;56(12):1205-1210
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To use a self-developed, prefabricated cap for making interocclusal records in implant-supported fixed prosthetic treatment, and to evaluate its effect of clinical application and accuracy of transferring intra-oral intercuspal position.Methods:Series of prefabricated caps for occlusal recording of implant-supported fixed prostheses were designed based on the healing abutments, and fabricated with three-dimensional (3D) printing. According to the inclusion and exclusion criteria, 12 partially edentulous patients who visited the Department of Prosthodontics, Peking University School and Hospital of Stomatology between November 2020 and September 2021, had lost no fewer than 2 contiguous teeth in distal extension (Kennedy Class Ⅰ or Ⅱ), and had received implant placement 3 months ago were enrolled. Self-control study design was used. Two occlusal records of each included case were obtained by the following 2methods:for the test group, appropriate prefabricated caps were used; and for the control group, polyvinyl siloxane occlusal record was directly set on the healing abutments. The working casts were mounted on the mechanical articulator using the 2 groups of occlusal records successively. Accuracy of occlusal relationship of the mounted casts was evaluated. Diagnostics test was performed to obtain the sensitivity and positive predictive value, which were determined in photographs by comparing the intra-oral occlusal contact points with those in the mounted casts, point-by-point. Virtual casts were taken by intraoral and extraoral scans in intercuspal position and imported to Geomagic Studio 2014. Then the root mean square values of occlusal clearance space between the upper and lower occlusal surfaces of remaining posterior teeth, and the deviations of the interocclusal position of the occlusal surfaces of the remaining teeth in the mandibular arches when superimposing the maxillary arches of the intraoral and extraoral scans were calculated. As a self-control design, paired t test was used. Results:Twelve participants were enrolled, including 3 men and 9 women aged (52.6±12.1) years, and 36 missing teeth. The prefabricated caps could fit on the healing abutments with good retention and stability. The sensitivity of the test group (0.73±0.14) was significantly better than that of control group (0.63±0.12, P<0.01), with no significant difference in positive predictive value between the 2 groups ( P>0.05). The deviations of the interocclusal position of the occlusal surfaces of the remaining teeth were (357.0±140.2) μm for the test group, and (399.4±206.3) μm for the control group, with no significant difference between them ( P>0.05). Conclusions:Interocclusal position record based on prefabricated cap in this study for implant-supported fixed prosthetic treatment can improve the consistency between the intra-oral occlusion and the occlusion in dental casts. This technique has good accuracy, clinical convenience and usability.