Study on pharmacokinetics of cefbuperazone in Chinese healthy volunteers
10.13699/j.cnki.1001-6821.2015.24.015
- VernacularTitle:注射用头孢拉宗在中国健康人体的药代动力学研究
- Author:
He-Kun MEI
1
;
Jin WANG
;
Rui WANG
;
Nan BAI
;
Bei-Bei LIANG
;
Jiang CAO
;
Ming-Jin TANG
;
Ken WEN
;
Xue-Wei JIANG
;
Hui NIU
;
Kai WANG
Author Information
1. 解放军总医院转化医学中心
- Keywords:
cefbuperazone;
pharmacokinetic;
high performance liquid chromatography;
plasma concentration;
urinary excretion rate
- From:
The Chinese Journal of Clinical Pharmacology
2015;(24):2417-2419
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the pharmacokinetics of cefbupera-zone in Chinese healthy volunteers.Methods The study was designed as an open, randomized, self-control study.12 subjects were received 1.0, 2.0, 3.0 g of cefbuperazone, respectively. Cefbuperazone was determined by high performance liquid chromatography. WinNonlin 5.2.1 software was used to calculate the pharmacokinetic parameters. Results Linear range of cefbuperazone was 2 -250 μg? mL-1 .The main pharmacokinetic parameters of three doses(1.0, 2.0, 3.0 g) of cefbu-perazone were as follows: Cmax were (81.74 ±15.95),(145.47 ±42.22), (198.16 ±36.03)μg? mL-1, tmax were (1.01 ±0.03),(1.02 ±0.04), (1.01 ±0.03), t1/2 were (1.80 ±0.30),(1.88 ±0.31),(1.74 ±0.27), AUC0-t were (136.37 ±43.31), (263.74 ±93.95), (335.76 ±68.47)μg? mL-1? h, respectively. Urinary recovery rate with 16 h was ( 45.24 ±17.50 )%, ( 48.27 ± 15.18 )%, ( 40.82 ± 14.24 )%. Conclusion The characteristic of cefbuperazone is linear.