Determination and analysis of reference interval of leukocyte-depleted suspended red blood cell volume in Xi′an
10.13303/j.cjbt.issn.1004549x.2024.09.013
- VernacularTitle:西安地区去白悬浮红细胞容量参考区间的确定与分析
- Author:
Xin CAO
1
;
Nana PING
1
;
Jin DING
1
;
Peng PENG
1
;
Na LIU
1
;
Yutong ZHANG
1
;
Na FENG
1
Author Information
1. Shaanxi Blood Center, Xi′an 710000, China
- Publication Type:Journal Article
- Keywords:
leukocyte-depleted suspended red blood cell;
rational use of blood;
capacity reference interval
- From:
Chinese Journal of Blood Transfusion
2024;37(9):1042-1046
- CountryChina
- Language:Chinese
-
Abstract:
【Objective】 To establish the internal quality control standard of leukocyte-depleted suspended red blood cell volume in our center, so as to guide the preparation of components, strengthen the internal quality control and improve the quality of blood preparations. 【Methods】 A total of 1 523 bags of whole blood collected using two manufacturers′ leukocyte-depleted blood bags from March to August 2023 at our center were extracted. The blood before and after filtration were weighed, and the volume of whole blood collected, the volume of filtration loss and the product volume based on the formula and measured specific gravity were calculated. According to the data distribution characteristics, the reference range of leukocyte-depleted suspended red blood cell volume was determined, and the differences of whole blood collection volume, filtration loss capacity and product capacity between the two manufacturers were analyzed. The quality control data of leukocyte-depleted red blood cells over the past year with the difference between another 100 bags of these cells and the reference interval were compared, and the effectiveness of reference interval was validated. 【Results】 The median whole blood collection volume in the sample size was 402.0 mL, with a median filtration loss of 42.4 mL, and an average volume of leukocyte-depleted suspended red blood cells at 322.5 mL. The whole blood collection volume (A: median 404.4 mL; B: median 397.7 mL, P<0.01) and the volume of leukocyte-depleted suspended red blood cell products (A: mean 331.4 mL; B: mean 312.0 mL, P<0.01) using manufacturer A′s leukocyte-depleted blood bag were both higher, with a lower filtration loss capacity (A: median 39.5 mL; B: median 46.6 mL, P<0.01). The standard deviation of the volume of leukocyte-depleted suspended red blood cell was 19.6, and the reference interval was 284.1-360.9 mL. The validation samples and quality control sampling data showed no difference from the interval samples (P>0.05). 【Conclusion】 According to the actual situation of our center, the volume standard of leukocyte-depleted suspended red blood cells in our center is determined to be 284.1-360.9 mL.