Mechanical Thrombectomy by the Rolling Technique Using a Coronary Wire in a Patient with Recurrent Inferior Vena Cava Filter Thrombosis.
10.3904/kjm.2015.88.3.303
- Author:
Jong Ik PARK
1
;
Su Hong KIM
;
Chang Bae SOHN
;
Sea Won LEE
;
Song Hee OH
;
Min Woong JEONG
;
Se Ryeong PARK
Author Information
1. Department of Internal Medicine, Busan Veterans Hospital, Busan, Korea.
- Publication Type:Case Report
- Keywords:
Vena cava filters;
Thrombosis;
Thrombectomy
- MeSH:
Humans;
Pulmonary Embolism;
Thrombectomy*;
Thrombosis*;
Vena Cava Filters*;
Vena Cava, Inferior
- From:Korean Journal of Medicine
2015;88(3):303-307
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
A permanent inferior vena cava (IVC) filter with anti-coagulation therapy may be considered in patients with recurrent pulmonary embolism. IVC filter thrombosis is a challenging clinical problem. Here, we report our experience in treating one such patient using mechanical thrombectomy via the rolling technique with a 0.014-inch coronary wire.