Detection value of double inversion recovery sequence in cerebral white matter hyperintensities in patients with acute ischemic stroke
10.3760/cma.j.cn115354-20240103-00007
- VernacularTitle:双反转恢复序列对急性缺血性脑卒中患者脑白质高信号病灶的探测价值研究
- Author:
Jiaqi CHEN
1
;
Yunlong YUE
;
Rui FU
;
Rui NIU
Author Information
1. 首都医科大学附属北京世纪坛医院神经内科,北京 100038
- Keywords:
Cerebral white matter hyperintensity;
Double inversion recovery;
Cerebral white matter hyperintensity penumbra
- From:
Chinese Journal of Neuromedicine
2024;23(2):140-145
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the detective effect of double inversion recovery (DIR) sequence on cerebral white matter hyperintensities (WMH) in patients with acute ischemic stroke, and compare with those of T2WI and FLAIR sequences.Methods:Seventy-three acute ischemic stroke patients with WMH within 14 d of onset, admitted to Department of Neurology, Beijing Shijitan Hospital, Capital Medical University from November 2018 to March 2021, were chosen. MRI T2WI, FLAIR and DIR sequences were used to detect WMH. According to Fazekas scale, patients with periventricular white matter hyperintensities (PVWMH) or deep white matter hyperintensities (DWMH) were divided into mild group (score of 0-1) and moderate to severe group (scores≥2); the differences in WMH volume detected by T2WI, FLAIR and DIR sequences, and signal intensity, cross-sectional area and contrast of isolated lesions were compared.Results:(1) Seventy-three patients were with PVWMH (36 into the mild group and 37 into the moderate to severe group); in patients from the moderate to severe group, PVWMH volume detected by FLAIR sequence was statistically larger compared with that by DIR sequence, and PVWMH volume detected by T2WI sequence was significantly smaller compared with that by FLAIR sequence ( P<0.05). Fifty-seven patients were with DWMH (44 into the mild group and 13 into the moderate to severe group); the DWMH volume detected by FLAIR and T2WI sequences was significantly larger than that by DIR sequence ( P<0.05). (2) A total of 60 isolated lesions were detected, ranged 5.0-9.1 mm in length; isolated lesions enjoying significantly larger cross-sectional area, higher signal intensity, and lower contrast detected by FLAIR and T2WI sequences compared with those by DIR sequence ( P<0.05); isolated lesions enjoying significantly higher signal intensity and contrast detected by T2WI sequence compared with those by FLAIR sequence ( P<0.05). Conclusion:DIR sequence enjoys better effect in detecting WMH than FLAIR and T2WI sequences; the mismatch area of DIR sequence with FLAIR or T2WI sequences suggests WMH penumbra.