Double-parameter three-dimension arterial spin labeling to evaluate collateral circulation in patients with unilateral chronic middle cerebral artery occlusion
10.3760/cma.j.issn.1671-8925.2018.06.012
- VernacularTitle:双参数3D-ASL在单侧大脑中动脉慢性闭塞的侧支循环评估中的应用价值分析
- Author:
Tiantao YE
1
;
Feng CHEN
;
Guanghui ZHANG
;
Zhongwei LI
;
Aijie WANG
;
Hui LIANG
;
Jianhua TANG
;
Guowei ZHANG
Author Information
1. 烟台山医院CT/MR室
- Keywords:
Three-dimension arterial spin labeling;
Chronic middle cerebral artery occlusion;
Collateral circulation;
Post-labeling delay
- From:
Chinese Journal of Neuromedicine
2018;17(6):605-609
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the application of double-parameter three-dimension arterial spin labeling (3D-ASL) in evaluating collateral circulation in patients with unilateral chronic middle cerebral artery (MCA) occlusion.Methods From May 2015 to November 2017,24 patients with unilateral chronic MCA occlusion were scanned in Yantaishan Hospital by conventional MRI,DWI,3D-TOF-MRA and 3D-ASL (post-labeling delays:1.5 s and 2.5 s respectively) using a 3.0 T MR scanner.The cerebral blood flow (CBF) values were measured in region of interest in the occlusive cortical area and in the contralateral normal cerebral area.The differences in CBF value measured by 3D-ASL (PLD=1.5 s and PLD=2.5 s) were analyzed by statistical methods.Results All the patients (n=24) on 3D-ASL (PLD=1.5 s) presented with apparent hypoperfusion in the MCA occlusion territory;but 3D-ASL (PLD=2.5 s) demonstrated the basically same perfusion in bilateral MCA territories,without apparent hypoperfusion in one cerebral hemisphere.The subtraction images of 3D-ASL (PLD 2.5 s-PLD 1.5 s)presented laminated high signal areas in the cortical region of MCA occlusion.There was no statistically significant difference in CBF value of the contralateral normal cerebral area between measurements by 3D-ASL (PLD=1.5 s) and by 3D-ASL (PLD=2.5 s) (6.39±5.01 mL/100 g·min versus 55.87±6.89 mL/100 g· min) (P>0.05).The CBF value of region of interest in the occluded cortical area (23.34±4.53 mL/100 g· min) was significantly lower than that in the contralateral normal cerebral area (55.87±6.89 mL/100 g·min) by 3D-ASL (PLD=1.5 s) (P<0.05).The CBF value of region of interest in the occluded cortical area (53.93±8.59 mL/100 g·min) by 3D-ASL (PLD=2.5 s) was significantly higher than that by 3D-ASL (PLD=1.5 s) (23.34±4.53 mL/100 g·min) (P<0.05).There was no statistically significant difference between the CBF value of region of interest in the occluded cortical area and that in the contralateral normal cerebral area by 3D-ASL (PLD=2.5 s) (P>0.05).Conclusions 3D-ASL (PLD=1.5 s and PLD=2.5 s) can noninvasively and intuitively demonstrate the collateral circulation compensation in patients with chronic MCA occlusion.3D-ASL (PLD=1.5 s) can reflect the first-order collateral circulation compensation while 3D-ASL (PLD=2.5 s) can reflect accurately the secondary collateral circulation compensation.