Ventricular puncture of deformation and displacement ventricle under real-time intraoperative ultrasound guidance
10.3760/cma.j.issn.1671-8925.2013.05.020
- VernacularTitle:实时超声引导下对变形、移位脑室行穿刺置管术探讨
- Author:
Wei ZHOU
1
;
Chun-Xiao MA
;
Ming LI
;
Chao HUANG
Author Information
1. 河南省人民医院神经外科
- Keywords:
Intraoperative ultrasound;
Ventricle puncture;
Hydrocephalus
- From:
Chinese Journal of Neuromedicine
2013;12(5):525-527
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the method of ventricular puncture of deformation and displacement ventricle under guidance of real-time intraoperative ultrasound.Methods Thirty-four patients with deformation and displacement ventricle,admitted to our hospital from January 2010 to January 2012,were performed ventricular puncture under real-time intraoperative ultrasound.The best puncture direction and depth were selected under monitoring of real-time intraoperative ultrasound.Results Thirty-four patients were conducted forty times of ventricle puncture,enjoying all success;postoperative CT scan or MRI showed appropriate location of the drainage tube in the ventricular cavity.No one was found serious secondary cerebral damage.Conclusion Intraoperative ultrasound can accurately position the deformation and displacement ventricle; utrasound-guided ventricular puncture,enjoying high success rate,is suitable for clinical application.