The comparison of diagnostic accuracy between biparametric magnetic resonance imaging and multiparametric magnetic resonance imaging in muscle-invasive bladder cancer
10.3760/cma.j.cn112330-20220908-00497
- VernacularTitle:bp-MRI与mp-MRI对肌层浸润性膀胱癌诊断效能的对比研究
- Author:
Peikun LIU
1
;
Xiao YANG
;
Lingkai CAI
;
Ruixi YU
;
Kexin BAI
;
Juntao ZHUANG
;
Kai LI
;
Qikai WU
;
Qiang CAO
;
Pengchao LI
;
Qiang LYU
Author Information
1. 南京医科大学第一附属医院,南京 210029
- Keywords:
Urinary bladder neoplasms;
Carcinoma;
Magnetic resonance imaging;
Biparametric;
Vesical Imaging-Reporting and Data System;
Diagnostic accuracy
- From:
Chinese Journal of Urology
2023;44(11):818-822
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the diagnostic accuracy between multiparametric magnetic resonance imaging (mp-MRI) and biparametric magnetic resonance imaging (bp-MRI) in muscle-invasive bladder cancer (MIBC).Methods:The clinical data of 195 patients with bladder cancer at the First Affiliated Hospital of Nanjing Medical University from July 2020 to June 2022, were retrospectively reviewed. There were 160 males and 35 females, with the median age of 68(61, 76)years old. Mp-MRI was performed on each patient within 6 weeks before transurethral resection of bladder tumor or radical cystectomy. Each patients’ images were divided into two sets. Set 1 (bp-MRI) included the axial, sagittal, coronal T2-weighted images (T2WI), and axial diffusion-weighted images (DWI) or apparent diffusion coefficient maps. Set 2 (mp-MRI) included Set 1 images in addition to dynamic contrast-enhanced images. All images were independently reviewed and evaluated by two radiologists. Mp-MRI was evaluated according to the Vesical Imaging-Reporting and Data System (VI-RADS)guideline, and bp-MRI was evaluated according to two types of criteria. Bp-MRI (Criterion A): VI-RADS scoring is determined 2 when T2WI 3-point with DWI 2-point. Bp-MRI (Criterion B): VI-RADS scoring is determined 3 when T2WI 3-point with DWI 2-point. VI-RADS scoring ≥ 3 or ≥ 4 was used as the cut-off value to predict MIBC. The sensitivity, specificity, positive predictive value, and negative predictive value of mp-MRI, bp-MRI (Criterion A), and bp-MRI (Criterion B) were calculated, as well as receiver operating characteristic curves and the areas under the curve (AUC).Results:Of 195 patients, 135 patients (69.2%) were pathologically confirmed as NMIBC and 60 patients (30.8%) were MIBC. When the VI-RADS cut-off value was ≥ 3, the sensitivity of mp-MRI, bp-MRI (Criterion A), and bp-MRI (Criterion B) were identical, all at 88.3% (53/60). The specificity of bp-MRI (Criterion A), bp-MRI (Criterion B), and mp-MRI were 88.9% (120/135), 73.3% (99/13), and 86.7% (117/135), respectively. When the VI-RADS cut-off value was ≥ 4, both bp-MRI (Criterion A) and bp-MRI (Criterion B) were classified as the same criterion. The sensitivity of bp-MRI and mp-MRI were 70.0% (42/60) and 75.0% (45/60), respectively. The specificity of bp-MRI and mp-MRI were identical, at 95.6% (129/135). The AUC for bp-MRI (Criterion A), bp-MRI (Criterion B), and mp-MRI were 0.927 (95% CI 0.881-0.959), 0.904 (95% CI 0.853-0.941), and 0.927 (95% CI 0.881-0.959), respectively. The AUC for bp-MRI (Criterion A) and mp-MRI were significantly higher than that of bp-MRI (Criterion B) ( P<0.001). There was no significant difference in AUC between bp-MRI (Criterion A) and mp-MRI ( P=0.939). Conclusions:Bp-MRI (Criterion A), VI-RADS scoring is determined 2 when T2WI 3-point with DWI 2-point, shows comparable diagnostic accuracy in predicting MIBC with mp-MRI. Compared to bp-MRI (Criterion B), the corresponding situation when VI-RADS scoring is determined 3, bp-MRI (Criterion A) may have better diagnostic accuracy than bp-MRI (Criterion B) in predicting MIBC.