Value of brain 18F-FDG PET/CT in the preoperative localization of epileptogenic foci in refractory epilepsy patients with negative MRI
10.3760/cma.j.cn321828-20231230-00151
- VernacularTitle:脑 18F-FDG PET/CT对MRI阴性难治性癫痫患者术前致痫灶定位的价值
- Author:
Chunyuan ZENG
1
;
Hailing ZHOU
;
Zhiqiang TAN
;
Guixian TANG
;
Huanhua WU
;
Biao WU
;
Yongjin TANG
;
Xueying LING
;
Qiang GUO
;
Hao XU
Author Information
1. 暨南大学附属第一医院核医学科,广州 510630
- Keywords:
Drug resistant epilepsy;
Positron-emission tomography;
Fluorodeoxyglucose F18;
Electroencephalography
- From:
Chinese Journal of Nuclear Medicine and Molecular Imaging
2024;44(4):196-201
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the value of 18F-FDG PET/CT for preoperative localization of epileptogenic foci in refractory epilepsy patients with negative MRI. Methods:Clinical data (550 lobes) of 55 epilepsy patients (38 males, 17 females, age (20.0±8.1) years) with negative MRI who underwent preoperative 18F-FDG PET/CT-MRI between January 2014 and June 2020 at the First Affiliated Hospital of Jinan University were retrospectively analyzed. The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of 18F-FDG PET/CT, video electroencephalogram (VEEG), PET/CT+ VEEG and PET/CT-VEEG for localizing epileptogenic foci were calculated using stereoelectroencephalography (SEEG) and the outcomes of at least 1 year of postoperative follow-up as reference standards. χ2 test was used to compare the efficiencies of different examination modalities for unilobar, multilobar and all patients. Results:The correct lateralization rate of epileptogenic foci was 92.6%(25/27) using PET/CT. The sensitivity, specificity, accuracy, PPV and NPV of PET/CT for localization of epileptogenic foci were 65.1%(54/83), 77.9%(364/467), 76.0%(418/550), 34.4%(54/157) and 92.6%(364/393), respectively. The sensitivities of PET/CT-VEEG for localization of epileptogenic foci in all patients and patients with multilobar epilepsy were higher than those of VEEG alone (75.9%(63/83) vs 45.8%(38/83), 68.6%(35/51) vs 31.4%(16/51); χ2 values: 15.80, 14.16, both P<0.001). The specificities of PET/CT+ VEEG for localization of epileptogenic foci in all patients and patients with unilobar epilepsy were higher than those of VEEG alone (97.6%(456/467) vs 94.6%(442/467), 97.9%(282/288) vs 94.1%(271/288); χ2 values: 5.66, 5.48; P values: 0.017, 0.019). The sensitivity of PET/CT-VEEG (PET/CT and VEEG concordance) for localization of epileptogenic foci was higher than that of PET/CT+ VEEG (PET/CT and VEEG discordance) (8/9 vs 28.4%(21/74); χ2=10.40, P=0.001), and its specificity and accuracy were higher than those of PET/CT-VEEG (PET/CT and VEEG discordance) (93.4%(57/61) vs 71.7%(291/406), 92.9%(65/70) vs 72.1%(346/480); χ2 values: 13.23, 13.96; both P<0.001). Conclusions:18F-FDG PET/CT can localize and lateralize epileptogenic foci in patients with negative MRI. The combination of 18F-FDG PET/CT and VEEG improves the sensitivity, specificity, and accuracy for epileptogenic foci detection. 18F-FDG PET/CT is more accurate in detecting epileptogenic foci when it is concordant with VEEG.