Abstract:
Objective:To investigate the clinical efficacy of femoral component revision surgery in addressing polyethylene sleeve wear in rotating hinge knee joints.Methods:A retrospective analysis was conducted on 21 patients who underwent treatment for polyethylene sleeve wear in rotating hinge knee joints at the Department of Orthopaedics, the Fourth Medical Center, PLA General Hospital, spanning from August 2008 to April 2023. There were 8 males and 13 females with a median age of 63(38, 76) years. Among them, 11 cases involved the left side, and 10 cases involved the right side. The average body mass index (BMI) was 25.0(22.5, 31.0) kg/m 2, and all cases underwent unilateral knee joint revision. The time interval from receiving the hinge knee joint prosthesis to revision was 10.5(6.0, 17.0) years, with 18 cases undergoing primary revision and 3 cases undergoing revision for the second time. Revision surgery of the femoral component sleeve was performed in all patients due to polyethylene sleeve wear. Visual analogue scale (VAS), range of motion (ROM) of the knee joint, changes in hip-knee-ankle angle (HKA), and Knee Society score (KSS) were collected and recorded to assess the surgical outcomes. Results:All patients were followed up for a median duration of 12.5(11.7, 13.4) months. Preoperatively, the VAS score was 5(3, 7) points, which significantly decreased to 0(0, 1) points at the last follow-up ( Z=5.721, P<0.001). At the last follow-up, the KSS scores decreased from 41.19±13.65 points preoperatively to 79.81±7.80 points, indicating a statistically significant difference ( t=12.560, P<0.001). HKA increased from 174.65°±5.20° preoperatively to 178.71°±2.79°, with a statistically significant difference ( t=5.533, P<0.001). Knee joint ROM increased from 69.05°±34.37° preoperatively to 110.00°±10.12°, also demonstrating a significant improvement ( t=5.960, P<0.001). Notably, patients exhibited knee joint stability with no passive flexion or extension laxity. Conclusion:Femoral component sleeve revision surgery effectively addresses polyethylene sleeve wear in rotating hinge knee joint prostheses, thereby mitigating the substantial loss of bone and soft tissue associated with overall revision procedures. The early postoperative clinical outcomes are promising and indicative of the efficacy of this surgical intervention.