Analysis of the eye lens dose and annual effective dose to some interventional radiation workers in Xinxiang city
10.3760/cma.j.cn112271-20230816-00049
- VernacularTitle:新乡市部分介入放射工作人员眼晶状体剂量和年有效剂量分析
- Author:
Yuxuan MAO
1
;
Bingjie ZHANG
;
Yulong LIU
;
Xuan WANG
;
Tongzhen LIU
;
Tianhe JIA
;
Fengling ZHAO
;
Quanfu SUN
;
Dianhui WANG
Author Information
1. 新乡市职业病防治研究所,新乡 453000
- Keywords:
Interventional radiation workers;
Eye lens;
Annual effective dose
- From:
Chinese Journal of Radiological Medicine and Protection
2024;44(3):216-222
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To analyze the eye lens dose and annual effective dose to interventional radiation workers in some hospitals of Xinxiang city from 2020 to 2022, and to ascertain the dose to interventional radiation workers.Methods:By using TLDs, the eye lens dose Hp(3) and annual effective dose Hp(10) were monitored for three consecutive years in six hospitals in Xinxiang city. The lens doses and annual effective doses to intervention radiation workers in different years in different-level hospitals and departments were analyzed. Results:From 2020 to 2022, a total of 117 people were monitored. The left eye lens dose range was 0.12-164.24 mSv, and the right eye lens dose range was 0.07-51.64 mSv. The average annual dose was 8.56 mSv for left eye lens and 4.49 mSv for right eye lens The average annual dose distribution in the MDL-5 mSv range for the left and right eye lens was 60.68% and 73.50%, respectively. 9.41% (11 people) of the left eye lens doses exceeded 20 mSv. The annual effective doses range was 0.11-31.27 mSv, with average annual dose of 2.56 mSv. The proportion of average annual effective doses mainly distributed in the range of MDL to 1.25 mSv was 52.14%, with 2.56% annual effective dose exceeding 20 mSv. There was no significant difference in left and right eye lens dose and annual effective dose between the tertiary hospitals and the secondary hospitals in three years ( P>0.05). Compared with different departments, the cumulative per capita dose in three years was statistically significant (left eye H=11.42, right eye H=13.72, annual effective dose H=25.94, P<0.05). The lens dose and annual effective dose in neurology department were lower than those in cardiology department and comprehensive intervention department ( Zcardiology department=-3.33, -3.78, -4.83, P<0.05; Zcomprehensive intervention department=-2.71, -2.63, -4.39, P<0.05). Conclusions:Most of the annual equivalent dose and annual effective dose to eye lens of the interventional radiation workers in Xinxiang city meet the national limits, but some of them have higher doses and exceed the national limits. It is suggested that the routine and continuous monitoring of eye lens doses to interventional radiologists should be strengthened while routine monitoring of annual effective dose, and attention should be paid to the eye lens and annual effective dose to interventional radiologists in secondary hospitals to improve the awareness of protection.