Impact of the LAmbre device on left atrial appendage adjacent structures and left atrium
10.3760/cma.j.cn131148-20230915-00113
- VernacularTitle:LAmbre封堵器对左心耳邻近结构及左心房的影响
- Author:
Zhengdan GE
1
;
Dehong KONG
;
Zhenyi GE
;
Chunqiang HU
;
Xiaochun ZHANG
;
Haiyan CHEN
;
Daxin ZHOU
;
Xianhong SHU
;
Cuizhen PAN
Author Information
1. 上海市影像医学研究所,上海 200032
- Keywords:
Echocardiography, transesophageal, real-time three-dimensional;
Left atrial appendage closure;
LAmbre device;
Mitral annulus;
Left atrium
- From:
Chinese Journal of Ultrasonography
2024;33(2):142-150
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the effects of the LAmbre device and mitral annulus(MA), as well as left atrium(LA) in patients with non-valvular atrial fibrillation(NVAF) after left atrial appendage closure (LAAC) using real-time-three-dimensional transesophageal echocardiography (3D TEE).Methods:Fity-six consecutive patients who underwent LAAC with the LAmbre device in Zhongshan Hospital of Fudan University from June 2019 to March 2023 were retrospectively enrolled, with no or less than moderate mitral regurgitation (MR). All patients underwent pre-operative and follow-up two-and three-dimensional transesophageal echocardiography (2D TEE, 3D TEE) at 60 days after the operation. The quantitative parameters of MA and LA were obtained by offline analysis using QLab 13.0 (Philips Healthcare, Andover, MA). Importantly, mitral annular measurements were made at seven time points throughout the cardiac cycle: early diastole, mid-diastole, late diastole, mitral valve closure, early systole, mid-systole, and late systole, which facilitates constructing the dynamic model of MA to assess the annular morphology and dynamics.Results:The values of AP diameter (APD), AL-PM diameter (ALPMD), 3D annulus circumference (3DAC), 3D annulus area (3DAA) decreased significantly compared with pre-operative values at all time points of the cardiac cycle (all P<0.05), while non-planar angle (NPA) and AH/CD were not apparently changed (all P>0.05 ). Throughout the cardiac cycle, MA showed regular changes, gradually increased in systole with the saddle shape deepened, and gradually decreased in diastole with the saddle shape shallowed.During systole, there was an increase in the rate of change of AP in MA [pre-operative (3.01±2.64)%, post-operative (3.81±3.51)%, P=0.037] after LAAC, with no significant difference in the rate of change of ALPM, 3DAC, and 3DAA.Meanwhile, we observed an evident reduction in LA minimal volume (LAVmin) [pre-operative (78.36±25.16)ml, post-operative (70.73±22.78)ml, P=0.004] and an obvious increase in LA ejection function [pre-operative (22.88±10.09)%, post-operative (31.41±12.28)%, P<0.05] during follow-up. Conclusions:3D TEE can accurately assess the impact of LAAC on the MA and LA. The LAmbre device can affect the morphology of MA, as well as the structure and function of LA, while the change of the dynamics of MA is not so prominent.