Application and diagnostic value of low dose scan technique of chest CT combined with 3D reconstruction for ribs in chest trauma
10.3969/j.issn.1672-8270.2024.01.011
- VernacularTitle:胸部CT低剂量扫描技术联合肋骨三维重建诊断胸部创伤的研究
- Author:
Wei PAN
1
;
Xiaodong WEI
;
Baoan CHI
;
Xutao FANG
;
Cui LI
Author Information
1. 解放军联勤保障部队第九〇四医院胸外科 无锡 214044
- Keywords:
Chest computed tomography(CT);
Low-dose scan technique;
Three dimensional(3D)reconstruction for ribs;
Chest trauma;
Diagnostic value
- From:
China Medical Equipment
2024;21(1):55-58
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the application and diagnostic value of low-dose scan technique of chest computed tomography(CT)combined with three dimensional(3D)reconstruction for ribs in chest trauma.Methods:A total of 118 patients with highly suspected rib fracture who admitted to the 904th Hospital of People's Liberation Army Joint Service Support Force were selected,and all cases underwent low-dose scan technique of chest CT combined with 3D reconstruction for ribs.The image qualities of chest CT scans with different low-doses combined with 3D reconstruction for ribs were analyzed,and the diagnostic accuracies among low dose scan technique of chest CT,3D reconstruction for ribs and the combination of them for chest trauma were compared.Results:Both the sharpness and clarity of the edges of the bronchi,blood vessels,lung parenchyma,interlobular septum,mediastinum and ribs were poorer,and the artifacts of soft tissue were more and the noise were more when the tube current of CT scan was 50 Ma.Both the sharpness and clarity of the edges of the bronchi,blood vessels,lung parenchyma,interlobular septum,mediastinum and ribs were general,and a part of soft tissues existed artifacts and the noise amounts were less when the tube current of CT scan was 70 Ma,which did not affect the diagnosis.The radiation dose as 50 mA was significantly higher than that as 70 mA,with a statistically significant difference(t=10.969,P<0.05).In 118 patients with chest trauma,the examination of low-dose scan technique of chest CT combined with 3D reconstruction for ribs indicated that there were 112 cases of rib fractures and 7 cases of costal cartilage fractures.In the examined 388 fractures of rib and costal cartilage,355 fractures(91.49%)were rib fractures and 33 fractures(8.51%)were costal cartilage fractures.In 118 patients with chest trauma,76 cases(64.41%)complicated with pulmonary contusions and lacerations,and 41 cases(35.75%)complicated with pleural effusion,and 10 cases(8.47%)complicated with thoracic vertebral fractures,and 6 cases(5.08%)complicated with splenic contusions and lacerations,and 5 cases(4.24%)complicated with mediastinal and subcutaneous emphysemas.The most direct imaging sign of rib fracture was visible and transparent low-density shadow.Chest CT scan can generally better display dislocation of the fractured end.The 3D reconstruction image showed a visibly line-like shadow on one side of rib if only one side of ribs fractured and the other side was intact.A total of 395 rib and costal cartilage fractures were confirmed by 3D reconstruction,which included 363 rib fractures(91.90%)and 32 costal cartilage fractures(8.10%).A total of 410 rib and costal cartilage fractures were confirmed by low-dose scan technique of chest CT combined with 3D reconstruction for ribs,which included 375 rib fractures(91.46%)and 35 costal cartilage fractures(8.54%).In the comparison of 418 rib injuries that were confirmed during surgery,the accuracy of low-dose scan technique of chest CT was 92.82%(388/418)in diagnosing rib and costal cartilage fractures,and the accuracy of 3D reconstruction for ribs was 94.50%(395/418)in diagnosing that,and the accuracy of low-dose scan technique of chest CT combined with 3D reconstruction for ribs was 95.69%(410/418)in diagnosing that.There was a significant difference in accuracy among the three types of examinations(x2=13.062,P<0.05).Conclusion:Low dose scan technique of chest CT combines with 3D reconstruction for ribs can be used in the diagnosis of chest trauma,which has higher accuracy and can provide reliable imaging information for clinical diagnosis and treatment.