Application of Forward Projected Model-Based Iterative Reconstruction Solution in Improving Image Quality of Head and Neck CT Angiography
10.3969/j.issn.1005-5185.2023.12.014
- VernacularTitle:全模型迭代重建算法在头颈CT血管成像中改善图像质量的应用
- Author:
Guoxuan WANG
1
;
Lei ZHANG
;
Ling LI
;
Juan CHEN
Author Information
1. 北京医院放射科 国家老年医学中心 中国医学科学院老年医学研究院,北京 100730
- Keywords:
Computed tomography angiography;
Head and neck;
Forward projected model-based iterative reconstruction solution;
Wide-body detector;
Hybrid iteration;
Low dose
- From:
Chinese Journal of Medical Imaging
2023;31(12):1309-1315
- CountryChina
- Language:Chinese
-
Abstract:
Purpose To explore the application value of forward projected model-based iterative reconstruction solution(FIRST)algorithm improving image quality of 100 kV low-dose head and neck CT angiography(CTA).Materials and Methods A total of 32 patients who underwent head and neck CTA examinations in the Beijing Hospital from September to October 2021 were retrospectively recruited.All patients were divided into three groups based on different reconstruction,including the filtered back projection(FBP)group,the adaptive iterative dose reduction 3D(AIDR 3D)group,and the FIRST group.The average CT value,image noise,signal-to-noise ratio,contrast to noise ratio and other objective indicators of the main blood vessels images(including common carotid artery,vertebral artery,internal carotid artery C1,C4,middle cerebral artery M1,M3 and anterior cerebral artery A1,A3)and background(including muscle,brain tissue)in the head and neck of the three groups were recorded and analyzed,respectively.The subjective imaging evaluation was scored and analyzed.Digital subtraction angiography(DSA)was used as the gold standard to evaluate the detection of vascular stenosis in the head and neck by each reconstruction algorithm.Results Compared with the AIDR 3D group and the FBP group,the FIRST group significantly reduced the image noise of the blood vessels and the background(muscle,brain tissue)(t=-13.19--7.28,all P<0.001).The signal-to-noise ratio and contrast to noise ratio of the FIRST group were significantly higher than those of the FBP group,AIDR 3D group(t=2.17-9.67,all P<0.001).The CT values of FIRST group were significantly higher than those of AIDR 3D group in the common carotid artery,internal carotid artery C1 and C4,middle cerebral artery M1,and anterior cerebral artery A1 segment(t=1.28-3.60,all P<0.05).The CT value of background(muscle,brain tissue)in FIRST group was significantly lower than those in the FBP group and the AIDR 3D group,with statistically significant difference(t=-7.63--4.03,all P<0.001).The images of FIRST group and AIDR 3D group met the diagnostic requirements,and the subjective scores of the two groups were significantly higher than those of the FBP group images(all P<0.05).The imaging scores of FIRST group were significantly higher than those of AIDR 3D group(P<0.05).Compared with DSA,FBP was ineffective for mild and moderate stenosis;FIRST and AIDR 3D algorithms were consistent with DSA.Conclusion Compared with traditional FBP and AIDR 3D reconstruction algorithms,FIRST algorithm can effectively improve the image quality of low-dose head and neck CTA and obtain better image quality and meet the diagnostic performance of head and neck vascular diseases.