Correlations between image quality and radiation dose in prospective and retrospective ECG-gated CT coronary angiography in patients with different heart rates
10.3969/j.issn.1005-202X.2024.02.010
- VernacularTitle:不同心率前后门控CT冠状动脉成像图像质量与辐射剂量的相关性分析
- Author:
Dechun ZHAO
1
;
Kebin YU
;
Jia LIU
;
Luxi YANG
;
Qi ZHU
;
Zhihua PAN
Author Information
1. 成都医学院第二附属医院(核工业四一六医院)放射科,四川成都 610051
- Keywords:
coronary angiography;
spiral CT;
prospective electrocardiogram-gated;
retrospective electrocardiogram-gated;
image quality;
radiation dose
- From:
Chinese Journal of Medical Physics
2024;41(2):185-190
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the correlations between image quality of prospective and retrospective electrocardiogram(ECG)-gated CT coronary angiogram and radiation dose in patients with different heart rates.Methods A total of 135 patients undergoing 256-slice spiral CT coronary angiography were enrolled in the study.Among them,66 cases received prospective ECG-gated scanning(prospective ECG-gated group)and further divided into two subgroups with heart rate≤80 beats/min(prospective ECG-gated+low heart rate subgroup,n=39)and>80 beats/min(prospective ECG-gated+high heart rate subgroup,n=27).The other 69 cases underwent retrospective ECG-gated scanning(retrospective ECG-gated group),including 45 cases with heart rate≤80 beats/min(retrospective ECG-gated+low heart rate subgroup)and 24 with heart rate>80 beats/min(retrospective ECG-gated+high heart rate subgroup).The baseline data,image quality[mean CT value,image noise,signal-to-noise ratio(SNR),subjective image quality score]and radiation dos[CT volume dose index(CTDIvol),dose length product(DLP),effective dose(ED)]were compared among 4 subgroups.The correlations of image quality with heart rate and radiation dose in prospective and retrospective ECG-gated groups were analyzed.Results The heart rates in prospective and retrospective ECG-gated+low heart rate subgroups were lower than those in prospective and retrospective ECG-gated+high heart rate subgroups(P<0.05).When comparing the mean CT value,image noise,SNR and subjective image quality score among 4 subgroups,no statistically significant differences were observed(P>0.05).The CTDIvol,DLP and ED in prospective ECG-gated+low heart rate subgroup were significantly lower than those in the other 3 subgroups(P<0.05),and the indicators in prospective ECG-gated+high heart rate subgroup were lower than those in retrospective ECG-gated group(including low and high heart rate subgroups)(P<0.05).Pearson correlation coefficient analysis revealed that the mean CT value,image noise,SNR,subjective image quality score had no significant correlation with heart rate,CTDIvol,DLP and ED in prospective and retrospective ECG-gated groups(P>0.05).Conclusion The subjective and objective image quality of 256-slice spiral CT coronary angiography is not correlated with radiation dose.Prospective ECG-gated scanning can reduce the radiation dose and ensure the image quality as compared with retrospective ECG-gated scanning.This holds true for eligible patients with high heart rate,and the former can effectively reduce radiation exposure.Therefore,prospective ECG-gated scanning is worthy to be promoted in clinic.