Development and application of a new type of assisted micro implant anchorage 3D guide plate
10.3760/cma.j.cn431274-20221106-01140
- VernacularTitle:一种新型助攻型微种植体支抗3D导板的研制和应用
- Author:
Yufeng GAO
1
;
Yu MA
;
Zhifei CHEN
;
Yanhua XU
;
Fangyong ZHU
;
Xiangbing WU
;
Deqiang HOU
Author Information
1. 江南大学附属医院口腔科,无锡 214021
- Keywords:
Dental implantation;
Micro-implant anchorage;
3D guide plate;
Precision implantation
- From:
Journal of Chinese Physician
2023;25(9):1325-1328
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To establish a computer-aided design and 3D printing system for precise implantation of micro implant anchorage, and accurately calibrate the position and direction of micro implant implantation.Methods:A retrospective selection was conducted on 15 patients (30 in total) who underwent micro implant implantation surgery from the Department of Stomatology, the Affiliated Hospital of Jiangnan University from November 2019 to November 2021, including 6 males and 9 females, aged (17.1±6.3)years old. The preoperative patient was photographed with cone beam computed tomography (CBCT) and the collected DICOM data format was output. A 3D scan was performed on the patient′s preoperative analysis model to obtain the STL file of the model scan. The CBCT data and model data were fitted and matched using 3Shape Implant Studio software, and the thickness of the guide plate, the amount of undercut compensation, and the size of the key component collar were designed. The 3D printer was used for printing after resizing. Using the assist method to implant micro implants, CBCT was taken postoperatively to compare the preoperative design with the postoperative results.Results:After fitting the postoperative CBCT with the designed CBCT of the micro implant, it was found that the micro implant was consistent with the preoperative design, maintained a safe distance and parallel to the adjacent tooth root, and did not damage the maxillary sinus and other areas. No detachment of the micro implant anchorage was observed 1 or 3 months after surgery. The application of assisted micro implant anchorage 3D guide plate was reliable, with accurate implantation position and direction, and can be implanted in most parts of the oral cavity.Conclusions:The use of computer-aided design and 3D printing system to create an assistive micro implant anchorage 3D guide plate can accurately locate the position and direction of the micro implant, which is worthy of clinical promotion and application.