Efficacy and Safety of Drug Coated Balloon for Coronary de Novo Lesions in Real World
10.3969/j.issn.1000-3614.2023.12.004
- VernacularTitle:药物涂层球囊在真实世界中治疗冠状动脉原发病变的有效性和安全性分析
- Author:
Rong LIU
1
;
Shubin QIAO
;
Jingang CUI
;
Hao GUAN
;
Haobo XU
;
Changdong GUAN
Author Information
1. 中国医学科学院 北京协和医学院 国家心血管病中心 阜外医院 冠心病中心,北京 100037
- Keywords:
drug coated balloon;
coronary;
de novo
- From:
Chinese Circulation Journal
2023;38(12):1254-1258
- CountryChina
- Language:Chinese
-
Abstract:
Objectives:To analyze the efficacy and safety of drug coated balloon for coronary de novo lesions in real world. Methods:We enrolled consecutive patients with coronary de novo lesions treated with drug coated balloons from January 2020 to June 2021 in Fuwai Hospital.The baseline data,procedure data and in-hospital cardiac events were collected through case query.All patients were followed up by clinical visit or telephone call.Major adverse cardiac events(MACE)were defined as the composite of the cardiac death,acute myocardial infarction,target lesion revascularization.According to the diameter of the blood vessels,the patients are divided into the large vessel lesion group(vessel diameter≥2.75 mm,n=337),and the small vessel lesion group(vessel diameter<2.75 mm,n=575). Results:There were 940 coronary de novo lesions in 912 patients.A total of 974 drug balloons were used,average diameter was(2.6±0.8)mm,average length was(21.0±6.0)mm,average pressure was(10.0±3.8)atm.Among the 940 primary coronary artery lesions,343 lesions had a diameter≥2.75 mm,and 597 lesions had a diameter<2.75 mm.During hospitalization,two patients with acute ST-segment elevation myocardial infarction died of cardiac rupture after emergency coronary interventional treatment,acute vessel closure because of coronary hematoma occurred in 1 patient and bailout drug-eluting stent was used in this patient,five patients received salvage stent treatment due to type C dissection immediately after drug coated balloon treatment.During follow-up,Target lesion revascularization(TLR)occurred in 15(1.6%)patients(including coronary artery bypass grafting in 1 patient).Nonfatal acute myocardial infarction occurred in 1 patient,cardiac death occurred in 1 patient,2 patients died of cerebral hemorrhage,1 patient died of cerebral infarction,MACE rate was 1.9%(17/912).MACE rate during follow-up was similar between large vessels group and small vessels group(1.8%vs.1.9%,P>0.05). Conclusions:Our study indicates that drug coated balloon for coronary de novo lesion is safe and effective.There is no difference of MACE rate between large vessel group and small vessel group.