Changes of Vital Signs, Expired Volume and Maximal Pressure by Mode of Ventilation during a Nuss Operation in Patients with Pectus Excavatum.
10.4097/kjae.2001.41.2.178
- Author:
Soo Dal KWAK
1
;
Nam Soon BAEK
;
Su Hyun CHO
;
Ki Ryang AHN
;
Sun Hak LEE
;
Chun Suk KIM
;
Wook PARK
;
Hyung Joo PARK
Author Information
1. Departments of Anesthesiology, College of Medicine, Soonchunhyang University, Cheonan, Korea.
- Publication Type:Original Article ; Randomized Controlled Trial
- Keywords:
nuss;
pressure control;
volume control
- MeSH:
Blood Pressure;
Funnel Chest*;
Heart Rate;
Humans;
Respiration, Artificial;
Tidal Volume;
Ventilation*;
Ventilators, Mechanical;
Vital Signs*
- From:Korean Journal of Anesthesiology
2001;41(2):178-183
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
BACKGROUND: This study was undertaken in order to investigate any cardiopulmonary changes caused by the surgical procedure during a Nuss operation in patients with pectus excavatum. METHODS: Thirty patients undergoing the Nuss operation were divided into two groups. The patients were randomly assigned to either Group-V (n = 15) which volume controlled ventilation was applied, or to Group-P (n = 15) where pressure controlled ventilation was applied. Mechanical ventilation provided a tidal volume to be set at approximately 10 ml/kg and a frequency set to keep ETCO2 in range, between 32 mmHg and 38 mmHg. During the surgical procedure, we recorded expired volume (VE) and inspired maximal pressure (Pmax) changes according to the ventilator mode, and then also recorded changes in vital signs. RESULTS: Heart rate and blood pressure had no significant changes in either groups. In Group-V, during rotation of the metal bar, there was a significant decrease in expired volume (P< 0.001), changes of inspired maximal pressure gradually increased with the operation (P< 0.001). In Group-P, rotation of the metal bar caused a significant decrease in expired volume (P< 0.001). CONCLUSIONS: During the Nuss operation, there should be careful observation of changes in the vital signs, expired volume and maximal pressure during insertion and rotation of the metal bar.