The effect of intraspinal blocking analgesia on delivery quality and puerperal pelvic floor function of primipara
10.3760/cma.j.cn115455-20221215-01103
- VernacularTitle:椎管内阻滞镇痛对初产妇分娩质量、产后盆底功能的影响
- Author:
Wei ZHANG
1
;
Li LI
;
Yanjuan ZHOU
;
Fengying CHENG
;
Junli WANG
Author Information
1. 芜湖市第二人民医院产科,芜湖 241000
- Keywords:
Parturition;
Analgesia, obstetrical;
Pelvic floor disorders;
Ultrasonography
- From:
Chinese Journal of Postgraduates of Medicine
2024;47(2):181-184
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the effects of intraspinal blocking analgesia on the delivery quality and puerperal pelvic floor function of primiparas.Methods:A total of 99 primiparas who delivered in the Second People′s Hospital of Wuhu City from January 2021 to April 2022 were enrolled in this study, 54 patients received intraspinal blocking analgesia (study group) and 45 patients received conventional treatment, without intraspinal blocking analgesia (control group). The delivery quality between the two groups was compared, and the pelvic floor function was evaluated and compared by pelvic floor rehabilitation therapy instrument and pelvic floor ultrasound at 6-8 weeks after delivery.Results:Vaginal delivery were successful in both groups. The total labor duration in the study group was longer than that in the control group: (8.03 ± 2.94) h vs. (6.89 ± 3.49) h, there was statistical difference ( P<0.05). The maximum value of pelvic floor rapid contraction stage, rising time and average value of continuous contraction stage in the study group were higher than those in the control group: (32.85 ± 10.13) μV vs. (14.73 ± 3.25) μV, (0.28 ± 0.06) s vs. (0.22 ± 0.05) s, (30.26 ± 5.24) μV vs. (16.74 ± 4.00) μV, there were statistical differences ( P<0.05). There were no statistical differences in other indicators such as the pre-resting stage, rapid contraction phase recovery time and post-resting stage between the two groups ( P>0.05). The rate of pelvic floor class Ⅰ and class Ⅱ muscle abnormalities at 6-8 weeks after delivery in the study group were lower than those in the control group, but there were no statistical differences ( P>0.05). The maximum Valsalva state hiatus area of levator ani muscle, maximum Valsalva state bladder posterior urethral angle, hiatus area of levator ani muscle at rest state and bladder neck degree in the study group were smaller than those in the control group: (19.09 ± 4.82) cm 2 vs. (23.00 ± 5.34) cm 2, (138.59 ± 23.14)° vs. (148.47 ± 20.38)°, (9.96 ± 2.63) cm 2 vs. (11.60 ± 2.75) cm 2, (20.13 ± 4.37) mm vs. (28.05 ± 6.52) mm, there were statistical differences ( P<0.05). Conclusions:Although intraspinal block analgesia can prolong the total labor time of primipara, but it can reduce the damage of pelvic floor function, possibly by increasing systolic period to protect pelvic floor muscles.