Preparation and application of adjustable body position protection belt for ordinary colonoscopy
10.3760/cma.j.cn211501-20230420-00967
- VernacularTitle:普通结肠镜检查可调式体位保护带的制作及应用
- Author:
Xiangfeng ZHU
1
;
Rong WANG
;
Xuning SHEN
;
Minfang CHEN
;
Wei WU
Author Information
1. 嘉兴市第一医院内镜中心,嘉兴 314000
- Keywords:
Nursing care;
Body position;
Colonoscopy;
Fixed device
- From:
Chinese Journal of Practical Nursing
2023;39(35):2741-2745
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the application effect of adjustable body position protection belt in patients undergoing not painless colonoscopy.Methods:A randomized and controlled trial was used, a total of 180 patients who planned to undergo not painless colonoscopy in the Endoscopy center, the First Hospital of Jiaxing from January to October 2022 were selected as the research objects. They were divided into the experimental group and the control group by the random number table method, with 90 cases in each group. The control group adopted the traditional method of colonoscopy body position placement, and on this basis, the experimental group used the adjustable body position protection belt to assist the patient body position placement. The maintenance rate of body position in colonoscopy, the cecal intubation time, the degree of intraoperative pain and the acceptance rate of re-examinationunder the same operating doctor and nurse were compared between the two groups.Results:The maintenance rate of body position in colonoscopy was 97.78%(88/90) in the experimental group and 58.89%(53/90) in the control group, the difference was statistically significant ( χ2 = 37.84, P<0.05). The cecal intubation time was (7.84 ± 4.39) min in the experimental group and (10.13 ± 5.85) min in the control group, the difference was statistically significant ( t = 2.98, P<0.05). The intraoperative pain score was 2.96 ± 1.39 in the experimental group and 4.28 ± 1.42 in the control group, the difference was statistically significant ( t = 6.31, P<0.05). The acceptance rate for re-colonoscopy was 88.89%(80/90) in the experimental group and 72.22%(65/90) in the control group, the difference was statistically significant ( χ2 = 7.98, P<0.05). Conclusions:Use of adjustable body position protection belt to assist body position placement before the patients undergoing not painless colonoscopy, it can improve the maintenance rate of body position during not painless colonoscopy, shorten the time of cecal intubation, reduce the intraoperative pain degree, and patients also have a higher willingness to undergo colonoscopy again.