Design and application of a new device for measuring postpartum blood loss after vaginal delivery
10.3760/cma.j.cn211501-20230605-01363
- VernacularTitle:新型阴道分娩产后出血量测量装置的设计及应用
- Author:
Xuemei FAN
1
;
Chunxiu ZHOU
;
Zhu ZHU
;
Aixia ZHANG
;
Liulan LI
Author Information
1. 南京医科大学附属妇产医院产房,南京 210004
- Keywords:
Postpartum hemorrhage;
Equipment design;
Blood loss assessment;
Vaginal delivery;
Obstetric nursing
- From:
Chinese Journal of Practical Nursing
2023;39(32):2481-2487
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the application effects of a new self-designed device for measuring postpartum blood loss in women with postpartum hemorrhage after vaginal delivery, so as to provide a basis for early identification and treatment of postpartum hemorrhage.Methods:The research was a quasi-experiment study. A total of 12 824 women who delivered vaginally in Women's Hospital of Nanjing Medical University from July 2021 to June 2022 were conveniently selected. Among them, the pregnant women enrolled from January to June 2022 were selected as the experimental group, and the pregnant women enrolled from July to December 2021 were included in the control group, with 6 412 cases in each group. The self-designed new postpartum blood loss measuring device was used to evaluate the blood loss in the experimental group, while the traditional blood collecting basin was taken in the control group.The differences between the two groups in the assessment error of 24 hours postpartum blood loss, postpartum blood loss at 2 hours and 24 hours, postpartum hemorrhage rate, severe postpartum hemorrhage rate and midwives′ satisfaction with the assessment of blood loss were compared.Results:The assessment error of 24 hours postpartum blood loss in the experimental group was 180.00 (80.00, 300.00) ml, which was lower than 192.00 (80.00, 310.00) ml in the control group, and the difference was statistically significant ( Z = - 2.04, P<0.05). The postpartum blood loss at 2 hours and 24 hours in the experimental group was 312.00 (290.00, 330.00) ml and 415.00 (385.00, 440.00) ml, respectively, which was higher than 310.00 (280.00, 330.00) ml and 407.00 (380.00, 435.00) ml in the control group, and the differences were statistically significant ( Z = - 9.86, - 5.42, both P<0.001). The rates of postpartum hemorrhage and severe postpartum hemorrhage in the experimental group were 6.50% (417/6 412) and 2.21% (142/6 412), respectively, higher than 4.71% (302/6 412) and 1.59% (102/6 412) in the control group, and the differences were statistically significant ( χ2 = 19.49, 6.69, both P<0.05). Midwives′ satisfaction score with the assessment of blood loss in the experimental group was (18.17 ± 1.02) points, higher than that in the control group (17.78 ± 1.17) points, and the difference was statistically significant ( t = 2.33, P<0.05). Conclusions:The use of a new device for measuring postpartum bleeding during vaginal delivery can reduce errors in evaluating postpartum blood loss within 24 hours, improve the detection rate of postpartum hemorrhage and severe postpartum hemorrhage, and midwives are satisfied with it.