Application of"rotation-correction loop technique"in the retrieval of complex inferior vena cava filters
10.3969/j.issn.1008-794X.2024.03.012
- VernacularTitle:Loop技术矫转法对复杂性下腔静脉滤器取出的技巧及应用效果分析
- Author:
Jie HU
1
;
Maolin QIAO
;
Qinqin TIAN
;
Heng WANG
;
Sheng YAN
;
Wenbo ZHAO
;
Yongbin SHI
;
Peilu SHI
;
Miao XING
;
Haifeng LI
;
Haijiang JIN
;
Ping WANG
;
Wenkai CHANG
;
Yuwen WANG
;
Honglin DONG
Author Information
1. 030001 山西太原 山西医科大学第二医院血管外科
- Keywords:
vena cava filter;
radiation dosa;
retrieval of inferior vena cava filter
- From:
Journal of Interventional Radiology
2024;33(3):289-294
- CountryChina
- Language:Chinese
-
Abstract:
Objective To discuss the application of the"rotating guidewire and correcting the filter recovery hook direction technique"("rotation-correction loop technique"for short),a technique invented by the authors in clinical practice,in the retrieval of complex inferior vena cava filter(IVCF),and to discuss its technical skills and advantages.Methods The clinical data of 417 patients carrying an IVCF,who were admitted to the Department of Vascular Surgery of Second Hospital of Shanxi Medical University of China to retrieve IVCF between January 2022 and December 2022,were retrospectively analyzed.Taking the time spent on the retrieval of IVCF and the intraoperative radiation dose as the evaluation indicators,the advantages and disadvantages of the standard filter retrieval technique,the"rotation-correction loop technique"and the other loop-assisted techniques were compared.Results Both the intraoperative radiation dose and the time spent on the retrieval of IVCF using"rotation-correction loop technique"were remarkably lower than those of other loop-assisted techniques(P<0.000 1).Conclusion For the retrieval of complex IVCF,especially for the IVCF which is heavily tilted and/or its recovered hook is attached to the vascular wall,the use of"rotation-correction loop technique"can shorten the time spent on the the retrieval of IVCF and reduce the intraoperative radiation dose.This technique carries high safety and practicability,the device is simple and it can be manipulated by single physician,which is conducive to clinical application and promotion.(J Intervent Radiol,2024,33:289-294)