Application of 3D-slicer software to measure renal volume parameters in evaluating renal function of renal transplant donors
10.3760/cma.j.cn115396-20231105-00126
- VernacularTitle:3D-slicer软件测量肾体积参数在评估亲属肾移植供者肾脏功能中的应用研究
- Author:
Mengmeng ZHENG
1
;
Chunkai DU
;
Limin SHANG
;
Lei ZHANG
;
Wen SUN
;
Zhipeng WANG
;
Yichen ZHU
;
Ye TIAN
Author Information
1. 首都医科大学附属北京友谊医院泌尿外科,北京 100050
- Keywords:
Imaging, three-dimensional;
Kidney transplantation;
Renal insufficiency;
Organ size;
Kidney volume;
3D-slicer software
- From:
International Journal of Surgery
2023;50(12):823-828
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the application value of 3D-slicer software in measuring renal volume parameters of renal transplant donors in evaluating renal function.Methods:The data of 31 renal donors admitted to Beijing Friendship Hospital, Capital Medical University from October 2019 to September 2022 were retrospectively analyzed. Glomerular filtration rate (GFR) were measured by SPECT radioactive dynamic imaging, and renal cortex volume (RCV), renal parenchymal volume (RPV) were measured after 3D reconstruction of urinary enhanced CT based on 3D slicer software. The estimated GFR(eGFR) predicted by creatinine-based GFR estimation equations (C-G equation, modified and simplified MDRD equation) and volume-based GFR estimation equations (Herts equation, Choi equation). Different eGFR were calculated, and the correlation between kidney volume parameters, eGFR equations and measured GFR was analyzed. The deviation, accuracy and consistency between different equations eGFR and measured GFR were analyzed and compared. The measurement data of normal distribution were expressed as mean±standard deviation ( ± s), and t-test was used for inter-group comparison. Measurement data with non-normal distribution were represented by M( Q1, Q3), and non-parametric test was used for comparison between groups. Results:The correlation between different eGFR and measured GFR is poor, and the deviation is small, and with good accuracy and consistency. Except for the weak correlation between the Choi equation eGFR and measured GFR ( r=0.382, P=0.034), there was no significant correlation between eGFR by other equations and measured GFR ( P>0.05). Among them, the deviation between the Herts equation-eGFR and measured GFR was the smallest (0.30 mL·min -1·1.73 m -2), with a 10% coincidence rate (61.29%) and a 30% coincidence rate (96.77%), and the best consistency with measured GFR, with a consistency limit of -28.75 to 29.34 mL·min -1·1.73 m -2. Conclusion:Compared with the laboratory index formula method, the Herts equation has better prediction efficiency in estimating GFR, The measurement of renal volume parameters by 3D slicer software has a certain clinical value in evaluating the renal function of renal donors, which is worthy of further application.